background image

7

Table of Contents

Important Safety Precautions  . . . . . .7
Technical data . . . . . . . . . . . . . . . .8
Getting Started  . . . . . . . . . . . . . . .8
Emptying and Servicing . . . . . . . . . .9
Declaration of conformity . . . . . . . .10

Important Safety 
Precautions

Repairs to the equipment should
only be carried out by Service Sta-
tions. Order spare parts from your
authorised dealer. If the required
parts are not in stock, he will pro-
cure them for you as quickly as
possible.

● 

This unit must be used solely for
supplying water to diamond drilling
rigs.

● 

Check the functioning of the unit each
time before startup, and make a spe-
cial check of the hose connection and
the screw connectors. Check the ma-
terial for tears, brittleness and corro-
sion.

● 

The safety valve must be checked
each time before startup! Insert the
pump and screw it up tight. Operate
the pump until the pressure gauge
shows no further increase (the safety
valve blows off the excess pressure).

The maximum pressure shown on
the pressure gauge must never ex-
ceed 6.6 bar.

● 

Do not leave the filled tank in strong
sunshine. Do not exceed operating
temperatures of 50°C.

● 

Store the unit in a place out of the
reach of children. 

● 

Do not leave a ready-filled unit unat-
tended at the place where it is being
used.

● 

Do not leave the unit under pressure
unnecessarily for longer periods of
time.

● 

Thoroughly clean out the tank imme-
diately after use and then dry it well
(see Emptying and Servicing).

● 

As a precautionary measure, we re-
commend that the water supply unit
be subjected to a particularly thorough
inspection every five years, preferably
by the manufacturer. 
Repairs to the tank are not permitted.

● 

Caution!

Please note that under product liabil-
ity law we are not liable for damage
resulting from the use of our product
if such damage was caused by im-
proper repair or if GLORIA-original
replacement parts were not used to
replace defective or worn-out parts
and the repair was not carried out 
by our Customer Service or by an 

GB

RZ_976213.qxd  12.03.2007  15:34 Uhr  Seite 7

Summary of Contents for Profiline 415 Series

Page 1: ...leitung 3 6 Instructions for use 7 10 Mode d emploi 11 14 DE GB FR Wasserzuf hrger t Water Supply Unit Cuve d Alimentation d Eau 0045 Ger te f r Industrie und Handwerk RZ_976213 qxd 12 03 2007 13 31 U...

Page 2: ...2 RZ_976213 qxd 12 03 2007 15 34 Uhr Seite 2...

Page 3: ...ersteigen Ein bef lltes Ger t nicht l ngere Zeit starker Sonneneinstrahlung ausset zen Betriebstemperaturen d rfen 50 C nicht berschreiten Ger t so aufbewahren dass es nicht von Kindern benutzt werden...

Page 4: ...lt 13 7 L zul Betriebs berdruck 6 bar zul Betriebstemperatur 0 C bis 50 C Voller Druckwechsel 0 bar bis 6 bar max 5000 Lastwechsel Beh ltermaterial Stahl mit Innenbe schichtung Sicherheitsventil siehe...

Page 5: ...erdruck von 6 bar roter Markie rungsstrich am Manometer im Be h lter erreicht ist berpr fung des Wasserstandes Abb Bei drucklosem Ger t roten Knopf dr cken durch Hochhalten des transparenten Schlauche...

Page 6: ...icherheits bedenklicher M ngel jedoch mindes tens alle 12 Monate haben Sachkun dige am besten der Wartungsdienst des Herstellers zu pr fen ob ein ge fahrloser Betrieb weiterhin m glich ist Die am Betr...

Page 7: ...maximum pressure shown on the pressure gauge must never ex ceed 6 6 bar Do not leave the filled tank in strong sunshine Do not exceed operating temperatures of 50 C Store the unit in a place out of t...

Page 8: ...pe 415 Item no 415 Max capacity 10 L Total tank capacity 13 7 L Max operating pressure 6 bar Max operating temperature 0 C to 50 C Full pressure change 0 bar to 6 bar max 5000 load cycles Tank materia...

Page 9: ...Check of water level Fig When the unit is not under pressure press red button hold upthe trans parent hose The water level in the hose is the same as that in the con tainer and it can be read off the...

Page 10: ...f defects affecting safe operation in particular but at a minimum every 12 months The national regulations applicable at the place of use regarding safety at work and the national regulations applicab...

Page 11: ...d pressurise La pres sion maximale indiqu e sur le manom tre ne doit pas d passer 6 6 bars Ne pas exposer trop longtemps le r servoir de produit de vaporisation en plein soleil Ne pas d passer des tem...

Page 12: ...415 Quantit de remplissage max 10 L Contenu global du r servoir 13 7 L Surpression de service autoris e 6 bars Temp rature de service autoris e 0 C 50 C Changement de pression de 0 bar 6 bar maxi 500...

Page 13: ...nt au moyen du flexible livr avec Actionner la pompe jusqu obtenir une surpression maximale de 6 bars rep re rouge sur le manom tre Contr le du niveau d eau Fig Lorsque la cuve n est pas sous pres sio...

Page 14: ...articulier de manques susceptibles d entraver la s curit et au moins une fois par an des sp cialistes de pr f rence des services d entretien du constructeur doivent v rifier si une utilisation sans da...

Page 15: ...RZ_976213 qxd 12 03 2007 15 34 Uhr Seite 15...

Page 16: ...976 601 00 03 2007 Brill Gloria Haus und Gartenger te GmbH www gloriaindustrialsprayer com RZ_976213 qxd 12 03 2007 13 33 Uhr Seite 5...

Reviews: