12
GB
N
4. the number of felt washers
(C)
used.
Observe the information given by the manufac-
turer of the medium.
l
In practice, sprayed liquids are a mixture of
various substances whose composition is
only known to the manufacturer. The suit-
ability of the unit for a specific liquid must
therefore be determined before use by the
user in conjunction with the manufacturer
of the substance.
Foreseeable misuse
l
The device is
not
suitable for:
- formic and hydrofluoric acid in any
concentration.
- acids and alkalis at concentra tions
greater than the amounts quoted or
as mixtures.
- oils and fuels.
- Media which may cause or promote cracks
and fissures in the plastics used.
- liquids at temperatures over + 40°C.
- inflammable liquids.
- very tenacious or sticky liquids, or liquids
that leave residues, which cannot be
completely poured or flushed out of the
unit (oils and oil-bearing liquids).
l
On request, the manufacturer of the unit
can make available a detailed list of the
materials used in the parts of the unit for
more detailed examination.
l
Unauthorised changes to the unit made by
the user or inappropriate use shall render
null and void the liability of the manufac-
turer for any damage caused as a result.
Getting Started
l
Unscrew the valve body
(B)
by rotating to
the left out of the container for filling.
l
Fill the tank, see ”Max. filling volume” in
the Technical data section and the tank
scale for details on the maximum amount
that can be put in.
l
Screw valve body
(B)
back in and pump up
the device. Observe the safety / pressure
relief valve
(A)
during pumping. Peak pres-
sure is reached when the safety / pressure
relief valve is triggered. Any excess pres-
sure will escape through the safety / pres-
sure relief valve.
WARNING!
Health risk through leaking cleaning
fluid!!
A leaking device or leaking components may
result in draining or spouting of cleaning fluid.
For this reason, observe the following safety
instructions:
- Check that the unit is in perfect condition
and properly sealed each time before use.
Pull up the safety / pressure relief valve
(A)
by hand and check that it returns to the
starting position.
- Only operate or move device when standing
upright.
- Inspect all screw joints for tight fitting.
WARNING!
Contact with cleaning fluids poses a
health risk.
Observe the max. filling amount (see
Technical Data) and the correct dosing given
by the spray producer.
FM10_DE_RU_80S_977091-02_final.qxp_Innenseiten_FM10.qxd 12.06.18 10:51 Seite 1
All manuals and user guides at all-guides.com