13
GB
N
l
The spraying process is initiated by press-
ing the push button
(G)
on the valve body.
Releasing the push button
(G)
immediately
interrupts the spraying process.
l
Pump up the unit again once the pressure
has dropped to around 1.0 bar so as to en-
sure a con sistent distribution of the
sprayed liquid.
Emptying and Service
l
Any residual pressure in the tank can be
vented by lifting up the knob on the safety /
pressure relief valve
(A)
.
l
Unscrew the pomp carefully, at first only a
few turns by left-hand rotation, so that com-
pressed air being still in the tank can escape.
Only then unscrew the pump completely
and take it out of the tank.
l
Empty and wash out the unit after use.
Note!
Any remaining liquid in the tank
can be emptied out completely through
the filler opening (in case of liquids haz-
ardous to waters see chapter “Important
safety instructions” and observe the in-
structions of the liquid manufacturer).
The type of flushing liquid to be used and
how it is to be disposed of will depend on
the details given by the manufacturer of
the liquid to be sprayed. Also consider
whether the tank is resistant to the flush-
ing liquid.
l
The pump will last much longer if the
pump O-ring is lubricated from time to
time with a little re si n- and acid-free
grease.
l
If foaming is no longer effective, check
whether the air inlet bores in the connecting
nipple
(E)
are clogged, clean them if re-
quired.
Note!
Above-average use due to manner
of operating (including the tranport to
the place of operation and the storage
when not using the sprayer), influences
of the surroundings (of the place of oper-
ation and the storage place), inadequate
maintenance and care may lead to an
early wear of the sprayer. Therefore, the
sprayer should be checked for secure and
serviceable state before use. It should at
least be checked for externally visible
damages.
Expecially when there occure damages
which endager the security, at least how-
ever after 2 years, the sprayer should spe-
cially be examined by one of the manu-
facturer’s service stations.
FM10_DE_RU_80S_977091-02_final.qxp_Innenseiten_FM10.qxd 12.06.18 10:51 Seite 1
All manuals and user guides at all-guides.com