206M 201805
28
Fig 7-3 Fig 7-4
7.3 Static (ST) balancing mode data input method and balancing operation
(
ST
)
mode is suitable for rims on which weights only can be sticked at middle position,
such as motorcycle rims.
Under normal mode, measure diameter d value ( Fig 7-5 )
,
press [d-] or [d+] to input d
value.
(
a value and b value can be any value
)
. Press [MODE] key to make ST mode
indication light on, enter static
(
ST
)
balancing mode, mode indication as following figure.
Fig 7-5
Input rim data, manually rotate wheel, when display shows “RUN ---”, move hand away
to let wheel rotate. Then right display shows ST and left display shows static imbalance
amount as Fig 7-6. After wheel stops rotating, slowly rotate wheel, when inside position
indication LEDs
(
Fig 5-1
(
10
)
)
and outside position indication LEDs
(
Fig 5-1
(
11
)
)
all light
,
stick weights equal to value shown on the left side display, at the 12 o’clock position of middle
rim ( Fig 7-5 ). Again manually rotate wheel, when display shows “RUN ---”, move hand
away to let wheel rotate. When both side display are on, wheel stops and balancing is
completed.
Fig 7-6
7.4 ALU-1mode data input method and balancing operation
Follow 7.2 to input rim data, press [MODE] key, mode indication as below figure, then
enter ALU-1 mode to balance wheel