Page 8
Loading/Unloading Labels
Unloading Remaining Label Roll
1. Open the side cover.
2. Release the printer head by pushing down on the release lever. See Figure 8-1.
3. Pull the winding bobbin lever outwards to loosen the paper wound around the winding bobbin; then remove
the paper from the winding bobbin.
4. Pull the stopper lever of the roll holder to make it straight; then remove the label roll from the path and the roll
holder.
Release Lever
Stopper Lever
Figure 8-1
Lock Lever
Winding Bobbin
Roll Holder
Initial Scale Set Up
Changing Current Date And Time
IMPORTANT
: Before using the scale for the first time, follow these steps to make sure that the current
date and time is displayed.
1. Make sure the scale is plugged in, turned on and there is nothing on the weigh platter.
NOTE:
The “Clock Check” screen will display. See Figure 8-2.
2. Press the Enter key on the keypad to proceed.
3. Key in 4000 and press the Mode key. The display will show: C00 ADJUST
4. Press the Enter key. Display will show : C01 DATE TIME
5. Key in 111111 and press the PLU key.
6. Press the Enter key. Display will show: C01-01 DATE and date displayed
7. Key in new date data.
Example: April 1, 2015
Key in 04012015
8. Press the Enter key. The date will be displayed as month, day and year. If date is correct, press the Enter
key. If not correct, key in the new date and press the Enter key. Display will show: C01-02 TIME and time
displayed
Figure 8-2
Time
Separators