Page 14
Setting Up Preset Function Keys
1. Make sure the scale is plugged in, turned on, and there is nothing on the weigh platter.
2. Key in 9000 and press the Mode key. The display will show: P00 PROGRAM
3. Key in 4 and press the Enter key. Display will show: P04 PRESET KEY
4. Key in 111111 and press the PLU key. Display will show: P04 PRESET KEY
5. Press the Enter key. Display will show: P04-01 000 0 000
6. Place the Operating Keysheet over the Scale Set-Up Keysheet. Press the desired preset key. Remove the
Operating Keysheet and note which preset key was used.
7.
Key in the desired preset function key flag number (see list below), press the Enter key.
8.
Key in 0 (Warning: Press the number 0, below number 1, NOT the →0←Zero key.) and then press the preset
key again to recognize the entry as the function key. Refer to Operating Instructions (Function Keys).
NOTE: Display will not change. To make sure that the preset key is set, select any other key on the
scale set-up keysheet and then the desired preset key again. Display should show the
selected key with the preset function key flag just keyed in.
NOTE: Two values can be stored on each preset key. The Lower Level preset function key is used to
switch between upper and lower level.
Preset function key flag
PLU
1
Auto
Manu
75
U/P (Unit Price)
32
Lower Level
156
Cassette Switching
435
Tare 2
Fixed
Price
3
X
(Multiply)
4
Special Price
5
-$ Price Discount
6
-% Percentage Discount
7
Save 8
9. Repeat steps 6 and 8 to set up additional keys. When completed press the Mode key three times to return to
normal operation.
Deleting Preset Keys
IMPORTANT: This procedure will delete ALL preset keys at once!
1. Make sure the scale is plugged in, turned on and there is nothing on the weigh platter.
2. Key in 9000 and press the Mode key. Display will show: P00 PROGRAM
3. Key in 4 and press the Enter key. Display will show: P04 PRESET KEY
4. Key in 111111 and press the PLU key. Display will show: P04 PRESET KEY
5. Press the Enter key.
6.
Press the →0← Zero key. Display will show 14033-0000 ENT OR CLR
Note: Press the Enter key to execute or the CLR key to stop.
7. There will be a long beep which signals that all preset keys have been deleted.
8. Press the Mode key three times to return to normal operation.
Preset Key Set Up