Globe GSP30B Instruction Manual Download Page 10

Page 10

Setting Up PLUs

 

1.  Make sure the scale is plugged in, turned on and there is nothing on the platter.
2.  Key in 9000 and press the Mode key.  Display will show:  P00   PROGRAM
3.  Press the Enter key. Display will show: P01 PLU
4.  Key in 111111 and press the PLU key.
5.  Press the Enter key. Display will show: P01-00 PLU >No<
6.  Key in the PLU number (5 digit maximum) and press the PLU key. Display will show: 13001-0000 ENT OR 

CLR.

NOTE: Press the Enter key to accept the PLU number or the CLR key to cancel. CLR will return you to 

the PLU number entry screen and Enter will move forward to the top of the PLU entry menu.

7.  Display will show: P01-01 <SALE1>
8.  Press the Edit key. See Figure 10-1.  Display will show: INP 0001-0000 00
9.  Use the Scale Set-Up Keysheet to key in the PLU name (24 character 

maximum per line, 2 line maximum, e.g. GROUND BEEF, BANANAS). See 

Figure 10-2.

10. 

Enter the first line of data. If you only want one line of data, then press the 

Enter key. If you want a second line of data, press the New Line key. Enter 

the second line of data, and press the Enter key to complete. See Figure 

10-3. Display will show: P01-01 <SALE1>

11.  Press the Enter key.  Display will show: P01-01-01 SALES   0
12. 

Key in 0 if the PLU is a weighing price item. Key in 1 if the PLU is a fixed 

price item.

NOTE: For weighing price items, proceed to step 13.  For fixed price 

items, proceed to step 18.

13.  Press the Enter key. Display will show: P01-01-04 PRICE 0.00
14.  Key in the unit price (5 digit maximum do NOT include decimal) and press 

the Enter key.

15.  Press the Enter key again.  Display will show: P01-01-10 TARE 0.000
16.  Key in the tare weight (4 digit maximum/2 digit minimum - tare weight is a 

three place decimal that must end in 0 or 5) or 0 if none and press the Enter 

key two times. Display will show: P01-01-12 P TARE 0.0

NOTE: For a detailed explanation of tares, refer to the Tare Weight 

section.

17.  Key in the tare percentage (3 digit maximum) or 0 if none and press the 

Enter key. 

NOTE: For weighing price items, proceed to step 26. 

18.  Press the Enter key. Display will show: P01-01-04 PRICE   0.00
19.  Key in the unit price (5 digit maximum) and press the Enter key.
20.  Press the Enter key again. Display will show: P01-01-06 QTY   0
21.  Key in quantity.  Press the Enter key.  
22.  Press the Enter key again.  Display will show: P01-01-07 UNIT TYPE 0
23.  Key in unit type. Press the Enter key.
24.  Press the Enter key again. Display will show: P01-01-09 FIX WGT 0
25. 

Key in fixed weight. Press the Enter key.

PLU (Price Look-up) Set Up

Figure 10-1

Figure 10-2

Figure 10-3

Line

Number

Total

Character

Number

PLU

Name

Line

Number

Character

Number

PLU

Name

Total

Summary of Contents for GSP30B

Page 1: ...tment at 937 299 8625 and ask for contact information for your local service company Model Serial IMPORTANT SAFETY NOTICE Visit our website for information on additional products available from Globe...

Page 2: ......

Page 3: ...1 LABELS 15 CASSETTE SET UP FOR SAFE HANDLING E12 LABELS 16 CASSETTE SET UP FOR INGREDIENT E13 LABELS 17 OPERATING INSTRUCTIONS PLU S Manual Label Print 19 Automatic Label Print Weighed Items 19 Autom...

Page 4: ......

Page 5: ...operation the general safety tips below must be followed DISCONNECT the scale from the power source unplug before servicing or opening ONLY trained and qualified service personnel should attempt repa...

Page 6: ...Check the level indicator to make sure the scale is level If the machine is not level weighing may not be accurate To adjust the machine to a level position rotate the four adjustment feet until the l...

Page 7: ...7 3 8 Insert the paper under the slot on the winding bobbin See Figure 7 3 9 Pull up on the stopper lever then slide it inwards to secure the label roll 10 Make sure the label paper is against the edg...

Page 8: ...e follow these steps to make sure that the current date and time is displayed 1 Make sure the scale is plugged in turned on and there is nothing on the weigh platter NOTE The Clock Check screen will d...

Page 9: ...r of the store name will display at a time Use the right arrow key on the Scale Set Up keysheet to cycle through the letters of the store name NOTE To enter one of the symbols not a letter select the...

Page 10: ...PLU is a weighing price item Key in 1 if the PLU is a fixed price item NOTE For weighing price items proceed to step 13 For fixed price items proceed to step 18 13 Press the Enter key Display will sho...

Page 11: ...r the POS point of sale number If the PLU number is to be in the barcode simply press the Enter key If the POS number is to be in the barcode key in the POS number 5 digit maximum and press the Enter...

Page 12: ...preset function key to switch between upper and lower level Setting Up Cassette Preset Functions Keys NOTE Up to seven cassette s can be programed Each cassette contains the label spec and label forma...

Page 13: ...stored on each preset key The Lower Level preset function key is used to switch between upper and lower level Refer to Operating Instructions Function Keys 7 Key in 2 for the preset function key flag...

Page 14: ...show the selected key with the preset function key flag just keyed in NOTE Two values can be stored on each preset key The Lower Level preset function key is used to switch between upper and lower le...

Page 15: ...play will show B11 04 FMT No 001 10 Press the End key Display will show B11 CASSETTE 11 Press the down arrow key on the Scale Set Up Keysheet one time Display will show B12 LABEL SPEC 12 Press the Ent...

Page 16: ...Enter key Display will show B11 04 FMT No 002 10 Press the End key Display will show B11 CASSETTE 11 Press the down arrow key on the Scale Set Up Keysheet one time The display will show B12 LABEL SPEC...

Page 17: ...the Scale Set Up Keysheet three times Display will show B11 04 FMT No 001 9 Key in format number 003 and press the Enter key Display will show B11 04 FMT No 003 10 Press the End key Display will show...

Page 18: ...Page 18 SAMPLES of all available labels for the GSP30B SAMPLE ONLY Standard GSP30B Label E11 SAMPLE ONLY Safe Handling GSP30B Label E12 SAMPLE ONLY Ingredient GSP30B Label E13...

Page 19: ...ight was not programmed for the PLU and it is needed do one of the following steps a Place the empty container on the weigh platter and press the tare key or b Enter the tare amount and press the tare...

Page 20: ...n the display will go off 4 Press the Mode key to return to normal operation Unit Price Used to print labels without the use of a PLU 1 Place product on the scale 2 Enter the unit price and press the...

Page 21: ...he PLU and press the PLU key or press one of the PLU preset keys 2 If the PLU is a fixed price item continue with step 3 If the PLU is a weighed item place the product on the receiving tray so a total...

Page 22: ...h a mild cleaner Never use volatile or caustic liquids Cleaning the Print Head 1 Dip a cotton swab into the thermal print head cleaning solution provided with the scale Isopropyl rubbing alcohol can a...

Page 23: ...platter 1 The machine is set in automatic mode Press the AUTO MANU preset key to switch the scale back to manual mode The AUTO indicator will go out of view Labels will not come out when print key is...

Page 24: ...ght of the container can be programmed into the PLU so that the container weight will automatically be deducted each time the product is weighed NOTE There are three different ways to manage the Tare...

Page 25: ...that the data will be stored in e g Data 01 02 03 ect Press the PLU key Display will show B27 02 SCALE TO USB NOTE Scale will pause After about five seconds backup will begin 10 Press the down arrow k...

Page 26: ...B00 SETUP 4 Key in 27 and press the Enter key Display will show B27 FILE SAVE LOAD 5 Press the Enter key Display will show B27 01 USB TO SCALE 6 Press the Enter key Display will show B27 01 01 I P SEL...

Page 27: ......

Page 28: ...ISE This warranty is given only to the first purchaser from a retail dealer No warranty is given to subsequent transferees This warranty does not cover product failures caused by failure to maintain n...

Reviews: