18.
Menu M3-Language
Using this menu you can select a language from the languages available. To go to the
next language press P2 to scroll up and P1 to scroll down. To confirm the chosen
language press the ON/OFF button (P3).
Menu M4- Standby
This menu can be used to activate or switch off the standby mode after selecting it,
using the buttons. It can be switched ON or OFF using P1 and P2.
Menu M5-Alarm tone
This menu can be used to switch the alarm on or off. Press the P1 or P2 button and
confirm with ON/OFF (P3) button.
Menu M6- Filling the first time (filling the auger)
This is only available when the stove is set to OFF. It allows the auger to fill up to start
the stove for the first time. After selecting the M6 menu, 'continue pressing' will appear
in the display. Press P2 to scroll up. The smoke extractor fan (LED 7) is switched on at
maximum speed. The auger is switched on (LED5) and both remain in this setting until
the time given on the display is reached or until the P3 button has been pressed. It is
possible that this setting is needed when the stove tank is completely empty and there
are no more pellets in the auger.
Menu M7 – Stove mode
After selecting the M7 menu by pressing the P3 button, the display will show the status
of some levels when the stove is in operation.
Menu M8- Technical settings (customer service)
This menu is reserved for the stove installer. After filling in the access code various
operational parameters can be installed with the buttons P1 and P2.
Menu M9 - backtrack
After selecting this menu with the P3 button, the menu will close and the settings will
be reset to the previous status.
19.
Operating system for the user
The following is a description of the normal operational settings installed in this pellet
stove.Turning on the stove: First connect the plug to the socket and then fill the pellet
tank. When filling make sure that the bag is not emptied in one go but that the tank is
filled gradually and slowly.
Any burnt remains must be cleared from the fire area and fire grate. The tank lid and
door must be closed. If this is not the case this can lead to the appliance
malfunctioning and eventually setting off an alarm. Press the P3 button for a few
seconds to ignite the stove. This will be shown in the display by 'ON' and by the
ON/OFF Led flashing. This stage takes a little time. The stove will now continue in
the preheating stage , the spiral filament and the smoke extraction fan (LED7) have
been activated. Any breakdowns during the starting up stage are shown in the
display and the stove shows the alarm status.
Filling the stove with pellets:
Filling the stove with pellets begins after approximately one minute. The sign “Fill
pellets will appear in the display and the ON/OFF LED flashes. During the first stage
the auger fills the fire grate with pellets. The smoke extractor fan is working and the
spiral filament is continually activated (LED 6 – ignition is burning). In the second
stage the auger is switched off (LED5- auger off), but the smoke extractor fan and
the igniter remain active. If no ignition takes place during this stage the auger will be
activated again for a certain time. The speed of the smoke extraction fan and the
spiral filament remain active.
Presence of fire:
After the exhaust temperature has reached and passed the settings required, the
system goes into the ignition mode, the sign 'flame on 'appears in the display and the
LED ON/OFF flashes. During this stage the temperature is checked to see if it
remains constant during a certain time. The speed of the smoke extraction fan and
the auger is set , (LED 5 auger is flashing) and the spiral filament is switched off
(LED 6 ignition switched off). Any breakdown will cause the stove to switch off and
the alarm stage will be activated.