2.
To keep the possibility of a guarantee our advice is to use a trained
specialist who will follow the current installation regulations when installing
the pellet stove.
This is a paid service for which you will need to make a separate appointment
.Together with our service partner we offer a maintenance contract for your stove.
A monthly payment covers the costs of a yearly maintenance, spare parts and
breakdowns.
This specialised engineer takes care of the initial installation as well as the
cleaning and maintenance of the stove. It is important that suitable fuel is used
and the owner cleans the stove regularly in the correct manner. If installation,
operating and maintenance instructions are not adhered to correctly the guarantee
will be invalid.
When using the stove for the first time please check that the fire grate has
been cleared and the pellet tank is empty and free of any residue.
The fire grate must be cleaned regularly. For maintenance we advise contracting
our service partner. All working parts of the stove will then be cleaned and tested,
preparing the stove for the next heating season.
Do not disconnect the electricity cable while the stove is in use.!!!
Operate the appliance with the help of the buttons on the display. De smoke
extraction fan must always be able to work to ensure the smoke is sucked
out through the chimney after use. If the electric plug is pulled out the fan
will stop working and the smoke will not be sucked out of the chimney.
Correct use, care and maintenance will lengthen the lifespan of the appliance.
Wastage and unnecessary environmental taxation will also be reduced.
Seite 2.
3.
Power supply
230 V AC / 50 Hz
Weight bearing capacity of floor
Make sure the floor has sufficient weight bearing capacity to take the weight of
the stove permanently.
Floor beneath and in front of stove
Floors which have flammable materials, such as carpet, parquet or cork must be
protected by a fire resistant plate which must be 30 cm wider at the sides,
measured from the side door /storage area of your stove and measuring at least
50 cm in front of the stove.
Chimney connection
The appliance must be connected to an approved chimney suitable for solid fuels.
The chimney must be 120 mm in diameter. Avoid too long a flue pipe to the
chimney. The horizontal length of the pipe must be no longer than 1.5 metres.
Avoid having the smoke change direction too many times leading up to the
chimney.
A maximum of three bends applies here. If it is not possible to connect the stove
directly to the chimney, a connecting piece with an opening for cleaning can be
used where possible. The connecting pieces must be made of metal and of an
approved standard. Installation must be airtight.
There must be a natural draught ensuring the removal of fumes, in case of a
temporary power cut, for example.