Global Power Technologies
1120 - Class I, Division 2, Group D, T3
If it is necessary to remove the fuel filter, the complete fuel assembly must be removed.
1)
Shut off fuel, disconnect the fuel input at point A.
2)
Disconnect the flexible fuel line at point B.
3)
Remove the two nuts holding the regulator to the mounting bracket (point D).
4)
Remove the four socket cap screws from the bottom of the regulator. Remove the bot-
tom, complete with the rubber gasket (see Figure 22).
5)
Remove and inspect the filter, clean or replace as required.
6)
Re-assemble in reverse order.
7)
Ensure that all joints are leak checked prior to starting generator.
36