background image

Model GLI-9143 Portable D.O. Meter

2

Rev. 0-401

Please read this instruction manual carefully
before using the instrument. This manual will
provide you with all the necessary information
for the correct use of the instrument, as well
as a precise idea of its versatility.

This meter is in compliance with European
Community (CE) directives EN 50081-1 and
EN 50082-1.

TABLE OF CONTENTS

PRELIMINARY EXAMINATION ................................. 2

GENERAL DESCRIPTION ..................................... 2-3

FUNCTIONAL DESCRIPTION -- PROBE .................. 3

FUNCTIONAL DESCRIPTION -- METER .................. 3

SPECIFICATIONS..................................................... 4

PROBE PREPARATION ........................................... 4

CALIBRATION ....................................................... 4-5

MEASUREMENT ................................................... 5-6

ALTITUDE COMPENSATION.................................... 6

SALINITY COMPENSATION..................................... 6

PROBE AND MEMBRANE MAINTENANCE........... 6-7

BATTERY REPLACEMENT ...................................... 8

WARRANTY.............................................................. 8

PRELIMINARY EXAMINATION

Remove the instrument from the packing
material and examine it carefully to make
sure that no damage has occurred during
shipping. If there is any damage, notify the
transit carrier immediately.

Each meter is supplied complete with:

 GLI-76407/4 Dissolved Oxygen Probe

with 13 ft. (4 m) cable or GLI-76407/10
Dissolved Oxygen Probe with 33 ft. (10 m)
cable

 Spare membranes (two)

 Protective cap

 30 ml electrolyte solution

 Instruction Manual

 AA size Alkaline Batteries (four)

 Rugged Carrying Case

NOTE:

Save all packing material until you
are sure that the instrument func-
tions correctly. All defective items
must be returned in their original
packaging together with the supplied
accessories.

GENERAL DESCRIPTION

The GLI-9143 is a water-resistant, micro-
processor-based, auto-calibration Dissolved
Oxygen meter with automatic temperature
compensation (ATC).

It has been developed for dissolved oxygen
and temperature measurement in water and
wastewater as well as other applications such
as fish farming.

Dissolved oxygen is indicated in hundredths
of parts per million (ppm = mg/L) or in % of
saturation.

The temperature range is indicated in centi-
grade from 0 to 50°C with 0.1°C resolution.

The ppm and the % saturation are both com-
pensated for changes in solubility of oxygen
in water and for permeability of the mem-
brane as well as the temperature effect.

Salinity compensation in water allows deter-
mination of mg/L of dissolved oxygen in salty
waters and the altitude compensation read-
justs for the altitude variance.

Four 1.5V AA alkaline batteries provide
power and make the instrument completely
portable. The meter is also designed to be
used with a battery charger or a 12VDC
power supply. A 12VDC input jack is incorpo-
rated into the housing.

A microprocessor ensures an accurate and
rapid calibration and measurement. The rug-
ged meter case is water-resistant for
maximum protection in the field as well as in
the laboratory.

Summary of Contents for GLI-9143

Page 1: ...Manual No 9143 Revision 0 401 MODEL GLI 9143 HAND HELD PORTABLE DISSOLVED OXYGEN METER ...

Page 2: ... material until you are sure that the instrument func tions correctly All defective items must be returned in their original packaging together with the supplied accessories GENERAL DESCRIPTION The GLI 9143 is a water resistant micro processor based auto calibration Dissolved Oxygen meter with automatic temperature compensation ATC It has been developed for dissolved oxygen and temperature measure...

Page 3: ... Polypropylene Probe Body 5 Temperature Sensor 6 O ring Seal 7 Silver Chloride Anode sensor element 8 Platinum Cathode sensor element 9 Oxygen permeable Teflon Membrane 10 Protective Cap FUNCTIONAL DESCRIPTION METER 1 Battery compartment 2 Probe connector 3 Liquid crystal display 4 ON OFF button 5 CAL button to enter or exit calibration mode 6 FACTOR button to select altitude F1 and salinity F2 7 ...

Page 4: ...76407A P supplied with the meter and make sure that the rubber O ring sits properly inside the membrane cap 4 Rinse the mem brane cap with electrolyte while shaking it gently Refill with clean electrolyte 5 Gently tap the sides of the mem brane cap with your finger tip to ensure that no air bubbles remain trapped To avoid damaging the membrane do not tap the membrane cap directly on the bottom 6 W...

Page 5: ...ss FACTOR and ensure F1 and F2 are set to the appropriate altitude and salinity values see ALTITUDE and SALINITY COMPENSATION NOTE The instrument must be calibrated whenever the probe membrane or the electrolyte is changed To exit the calibration mode during calibration press CAL The display may be switched from readings in saturation to ppm without re calibration by simply pressing RANGE MEASUREM...

Page 6: ...y will show the measured temperature in degrees Celsius Allow the probe to reach thermal equilibrium with the sample before taking any measure ment The greater the difference between the ambient temperature and the temperature of the sample the longer it will take the probe to equilibrate to the sample ALTITUDE COMPENSATION Press FACTOR and F1 will be displayed Use the UP and the DOWN keys to set ...

Page 7: ...shed or stained which could be due to contact with certain gases or extended use with a loose or damaged mem brane the cathode should be cleaned 1 Use a clean lint free cardboard or cloth and rub the cathode very gently side to side 4 5 times This will be enough to polish and remove any stains without damaging the platinum tip 2 Rinse the probe with deionized or dis tilled water 3 Install a new me...

Page 8: ...Meter to be free from defects in material or workmanship for a period of one year 12 months from the date of shipment of this product from our facility The GLI 76407 4 or GLI 76407 10 Dissolved Oxygen Sensor is warranted for a period of 6 months A war ranty claim will not be honored if defects are not reported within the warranty period or if GLI International determines that defects or damages ar...