background image

GUIDE TO:

!

!

DESCRIPTION

!

!

INSTALLATION

!

!

OPERATION

740 Century Circle

Conway, SC 29526

Phone: (843) 399-6146

Fax: (843) 399-5005

www.glendinningprods.com

G

G

G

G

L

L

LL

E

E

E

E

N

N

N

N

D

D

D

D

I

I

II

N

N

N

N

N

N

N

N

I

I

II

N

N

N

N

G

G

G

G

C

C

ABLEMASTE

ABLEMASTE

R

R

Shore Power Cable Storage System

SML-CMMAN

PRINT DATE:  06/08

740 C

ENTURY

C

IRCLE

C

ONWAY

, SC 29526-8274

USA

PRODUCT WARRANTY INFORMATION

PLACE

STAMP

HERE

CM-7 for 

50 amp

CM-4 for 

30 amp

CM-8 for 

100 amp

Diameter 3-5/8"

cut on outside

of line 

Diameter 17/64"  4 Plcs.

Hawse Pipe 

Template

Summary of Contents for Cablemaster

Page 1: ...Conway SC 29526 Phone 843 399 6146 Fax 843 399 5005 www glendinningprods com G G G G L L L LE E E EN N N ND D D DI I I IN N N NN N N NI I I IN N N NG G G G C CABLEMASTE ABLEMASTER R Shore Power Cable...

Page 2: ...nsists of two major components the hawse pipe and power unit The chromed hawse pipe is designed to accommodate varying sizes of shore power cables with the attached 30 or 50amp shore power plug cover...

Page 3: ...ble The CM 4 usually comes attached to it s own storage container to make installation as easy as possible You may also order the CM 4 with TV telephone cable installed instead of 30 amp shore power c...

Page 4: ...so be careful to remember that the selection of the hawse pipe location is in a large measure determined by the prop er location of the power unit and cable storage area Be sure that the hawse pipe s...

Page 5: ...limit switch by extending the wire to the relay box Fig 4 OTHER INSTALLATION OPTIONS Any number of mounting arrangements can be accomplished using the PVC pipe to remote mount the power unit or guide...

Page 6: ...gh a PVC pipe you are now ready to wire the Cablemaster to the boat s DC electrical system If the shore power cable is being direct ed vertically through PVC pipe see drawing below it is necessary to...

Page 7: ...limit swithch which is connected to the 1 and 2 terminals on the barrier strip is activated when the plug cover touch es the switch The out limit switch which is connected to the 3 and 4 terminals of...

Page 8: ...or in the appropriate hole with the optional bezel see accessories In each case the power switch must be protected by the neoprene cover to prevent the intrusion of moisture The relay box is mounted o...

Page 9: ...con nection to the electrical system E CABLE ADJUSTMENT Shore power cable diameters vary from one cable manufacturer to another the Cablemaster s main pulley is split in half and proper friction adjus...

Page 10: ...xes receptacles breakers and other enclosures in which electrical connections are made should be waterproof or be installed in a protected area Electricity enters the boat through the power cable The...

Page 11: ...l either no power or unit has power and does not respond Tripped breaker Power wire incorrectly connect ed to relay assembly Defective motor Defective relay box Reset breaker Replace relay assembly Wi...

Page 12: ...mp 220 v Adjustable 7 8 1 1 4 dia Length capacity Determined by size of storage location CM 7 DIMENSIONS 5 5 127 mm Hawse Pipe Flange Dim 5 x 6 1 2 3 1 2 89 mm 4 3 4 121 mm 9 3 4 248 mm 15 3 4 400 mm...

Page 13: ...DIMENSIONS Specifications Voltage Amperage Dimensions Weight Capacity Length of cable 12v DC or 24v DC 4 5 amps under load 5 1 2 L x 6 W x 10 H power unit only 9 lbs 30amp 110 volt cable 3 4 diameter...

Page 14: ...8 3 8 213 mm 4 102 mm SPECIFICATIONS Voltage 12v DC 24v DC available Current 7 11 Amps under load Weight 40 lbs Power unit 12 lbs Hawse pipe Cable size up to 2 gauge 5 conductor 100amp Adjustable 1 32...

Page 15: ...ASSEMBLY 50421 HINGE 50420 CAP RELAY ASSEMBLY 04034 12 24 VOLTS 70005 U BOLT 2X 65001 Spacer 50415 CHASSIS COVER 50414 CHASSIS 04812 IN LIMIT SWITCH ASSY incl switch 2 ft wire assy protective boot 048...

Page 16: ...mt Yellow or Purple ORANGE BLACK OFF OUT IN POWER SWITCH RED WHITE BLACK IN LIMIT SWITCH OUT LIMIT SWITCH M 12 or 24v MOTOR BATERY POSITIVE BATTERY NEGATIVE WHITE RED BLACK CABLEMASTER WIRING DIAGRAM...

Page 17: ...DINNING MARINE PRODUCTS INC for instructions concerning removal and shipping of the defective component Upon compliance of the foregoing procedure all warranted defects will be repaired or at GLENDINN...

Page 18: ...ge of transmitter Relay Unit required for addition of Remote on CM 4 models 85448 85424 85420 85421 POWER CABLE STORAGE CONTAINERS rotationally molded styrene containers used to store shore power cord...

Page 19: ...DOUS MISUSE CAN RESULT IN FIRE OR DEATH BY ELEC TRICAL SHOCK PLEASE READ CAREFULLY AND FOLLOW INSTRUCTIONS HAZARDS STATEMENT N OR SEND VIA FAX TO 843 399 5005 A cord reel marked for indoor use is to b...

Page 20: ...SML CMMAN PRINT DATE 06 08 740 CENTURY CIRCLE CONWAY SC 29526 8274 USA PRODUCT WARRANTY INFORMATION PLACE STAMP HERE Diameter 3 5 8 cut on outside of line Diameter 17 64 4 Plcs Hawse Pipe Template...