Page 6
Standard Equipment
The standard confi guration of the PulsaCoil BP
is shown opposite.
1. Drain - 1/2” BSP
2. Cold water inlet (22mm)
3. Hot water outlet (22mm)
4. Bottom (off -peak) immersion heater (3kW)
5.
Top (on-peak) immersion heater (3kW)
6.
Scale inhibitor PCB - (factory fi tted
optional extra)
7.
Hot water thermostatic blending valve
8.
Cold feed/expansion pipe (15mm)
9.
Open vent pipe (22mm)
10. Manual
fi ll sight glass for top up cistern (not
shown)
Note :
Both immersion heaters are low watts
density type with incaloy 825 sheaths and are
specially manufactured to suit Thermal Stores.
It is recommended that any replacements
should be obtained from Gledhill Building
Products.
Optional Extra Equipment
•
In line scale inhibitor for mains water
services with hardness levels between
200 and 300ppm (mg/l) fi tted but ready
for wiring by the installer to the suitable
230V ac supply.
•
Polyphosphate scale inhibitor for fi tting on
site by the installer.
• Ballvalve/overfl ow connector for top up
cistern.
Figure 1.2
6
8
3
7
2
1
4
5
9