BIK-E
Beer Panel Installation Instructions
F-750-361 Rev. A
These instructions assume that the primary regulator and CO2 line to the walk-in cooler are already installed.
1. Position the regulator panels according to factory instructions.
2. Connect CO2 source line to one end of regulator bank (A). If there is more than one panel, continue the line
to the next panel until all panels are connected
3. Attach an Empty Keg Detector (B) to each of the black EKD mounting brackets by sliding them in place. The
EKD can be mounted to flow left or right.
4. Approximately 9 feet of clear vinyl beer line (C) is provided for the keg jumper line from each keg to its
EKD. Trim clear line to size and attach one end to bottom input port of the EKD and the other end to the keg
tap.
5. Approximately 9 feet of red air line (D) is provided for the jumper line from each keg to its regulator (E).
Trim red air line to size and attach one end to the regulator and the other end to the keg tap.
6. Attach the polyline (F) from the beer line set (conduit) to the side output port of each EKD.
7. Approximately 6 feet of exhaust line (G) is provided for the exhaust port of each EKD. Trim the exhaust
line to length and attach to each EKD exhaust port so the exhaust can be drained to a bucket. No clamp is
required.
8. The keg regulators (E) provide individual pressure to each keg. Upon start up, the ideal gauge pressure will
depend on the type of gas involved as well as the length of the line runs. The goal is to achieve a flow rate of
2 ounces per second.