Installation using Optional 
Installation Lid

Installation using 

Ducting and Optional 

Angled Bend

If using 100mm ducting, cut to size and snap fit onto angled 

bend (if applicable) as shown above. 

If using 50mm ducting slot inside 

Concrete-In Plate as shown. 

If using an optional 

Installation Lid remove 

all four fixings (Kit 

Contents H & I), 

position the 

Installation Lid onto 

the plate ensuring the 

holes are aligned and 

re attach the fixings as 

shown.  Remove Lid 

when concrete has set 

and LED Housing is to 

be pluged in.

Installation

Lid

Dig a hole to the minimum dimensions (see Diagram A) 

taking care to avoid buried services.

If using ducting (50mm or 100mm), excavate trench to the 

recommended depth to accept the incoming 24 Vac 

supply.

Note: Alternatively 24V armoured cables may be layed by 

slot cutting the road surface.

Remove approximately 60mm of the armouring to expose 

the internal cable (maximum diameter 8.1mm).

Remove the Plug (Item 11) from the 24V LED Unit (Item 6) 

by unscrewing then pulling from the unit.

Disassemble the plug (Item 11) by unscrewing the centre 

ring and gland (see Diagram C) and remove centre to 

expose cable terminals.

Insert cable through gland, connect cables to terminals and 

re-assemble Plug ensuring the gland is tightened to 

maintain ingress protection.

Assemble the ducting to the Concrete-In Plate (Item 7) as 

shown in diagram B, and position in the previously 

prepared hole.

Ensure the Concrete-In Plate is level using a spirit level. Also 

ensure the plate is at ground level, support blocks or gravel 

may be required to achieve this (see Diagram D).

Ensure the Plate is in the correct orientation and feed the 

cable/plug through the centre of the Concrete-In Plate.

If using an Installation Lid follow guidelines in Diagram E.

Pour concrete into hole ensuring the Concrete-In Bars (Item 

10) are fully covered and the hole is completely filled (see 

Diagram F). Allow to set.

Gland

Support Block

Unscrew plug anticlockwise