23
EN
USER’S GUIDE
BC-BCP
Adds the actual operation to the accumulator
. Up to 99 values can be added or different values can also be
added up to the maximum capacity of the weight display.
MR
To recover the memory of the accumulator.
SAMPLE
It is used to introduce the weight of the sample manually.
U.Wt
It is used to introduce the weight of a sample manually.
Pst
This key is used to fix the upper limit of the number of items which have been counted. When this upper limit is exceeded,
the acoustic alarm of the balance scale is going to sound.
It is used to print the results to a PC or printer using the optional RS.232 interface.
5. SCREEN
DISPLAY DESCRIPTION
The scales have three displays. The displays show WEIGHT, UNIT WEIGHT AND QUANTITY
DISPLAY OF THE WEIGHT
DISPLAY OF THE UNIT WEIGHT DISPLAY OF UNITS
It is the display that indicates the weight place on
the scale.
The arrows on the symbols are going to indicate the
following information: Low Battery Indicator.
Indicator of net weight, “Net”, indicator of stability,
“Stable”, Indicator of Zero, “Zero”.
This display is going to show the unit weight of
a sample. This value can be introduced by the
user or calculated by the balance scale. The
unit of measure are the grams in all the scales.
The indicators are going to show when the
balance scale has determined that there is an
insufficient number of samples to determine
properly the number of pieces. It will be show
when the symbol “sample” appears in the
screen. When the unit weight is not enough
big to determine an accurate and complete
count, the balance scale is going to highlight
it by showing in the screen the symbol
“U.Wt”. In both cases the balance scale will
continue operating and the indicators are
going to alert the user that there is a problem
in the process. If a prefixed recount has been
stored the symbol “Preset” or “Pst” are going
to appear with an arrow above them.
This display is going to show the number of items
placed on the scale or the value of the accumulated
recount. The user must refer to the section BASIC
OPERATIONS. The indicators are going to show
when a value has been introduced in the memory
by showing an arrow above the “Memory” message
in the display.
Immediately, under the display of quantity there
is a LED that indicated the state of the charge of
the battery. When the scale is switched on to the
electricity grid, the internal battery is going to be
charged. If the LED is green, the internal battery
has been charged completely. If the LED is red, the
internal battery has been completely discharged.
If the LED is yellow, the internal battery is being
recharged.