background image

25

GB

Safety instructions

Installation and mounting of electrical devices may only be carried out by qualified 
electricians.
Failure to observe the instructions can result in damage to the device, fire or other 
dangers.
Danger of electric shock. Isolate before working on the device. Take account of all 
circuit breakers supplying dangerous voltage to the device.
Do not operate the device with sharp objects. This may damage the touch-sensitive 
surface.
Do not use sharp objects, acids or organic solvents for cleaning. These may damage 
the device.
These instructions are part of the product and must remain with the end customer.

Device design

3

2

4

1

5

6

8

9

11

12

10

7

13

15

16

14

Summary of Contents for Control 19

Page 1: ...Installation and Operating Instructions Control 19 2088 00...

Page 2: ......

Page 3: ...the device 30 For 230 V AC installation 32 For 24 V DC installation 32 Retrofitting the earth connection for the flush mounted box of the Gira Pro face ServerClient 15 33 Mounting and electrical conne...

Page 4: ...24 GB...

Page 5: ...shock Isolate before working on the device Take account of all circuit breakers supplying dangerous voltage to the device Do not operate the device with sharp objects This may damage the touch sensiti...

Page 6: ...holder 17 230 V AC connection 6 Mount for design frame 18 Fuse 7 Mounting holes 19 24 V DC connection 8 Camera 20 2 x USB connections on rear 9 Camera cover plate 21 Network connection 10 Camera oper...

Page 7: ...pixels 16 7 million colours Windows Embedded POSReady 2009 operating system Touch screen operation via touching with finger directly on screen 24 V DC or 230 V AC power connection Horizontal installat...

Page 8: ...lly pull the design frame downwards Switching on The design frame 1 has been removed the on off button 16 is accessible Switch on Press the button 16 The operating system starts up Switch off Briefly...

Page 9: ...special touch screen stylus not included in the scope of supply Graphic interface A mouse pointer that follows the operation of the touch screen is used for operation Short operations of the screen ar...

Page 10: ...until the device is restarted Previous data are restored if the device is switched off or if there is a power failure Modifications in the My Documents directory are not write protected and are always...

Page 11: ...l appropriate circuit breakers before working on the device Cover up live parts in the vicinity i Note Mount at eye level for optimal reading i Note Observe the mounting instructions for the flush mou...

Page 12: ...l 21 of the Control 19 Mount the Control 19 in the flush mounted box Use the included screws for this Insert the design frame into the intended mounts and carefully pull down For 24 V DC installation...

Page 13: ...holes into the rear wall of the flush mounted box Fig 2 Fasten both earthing wires to the flush mounted box Fig 3 Connect the 230 V AC mains connection cable to the 230 V AC connection 17 of the Contr...

Page 14: ...s after approximately three seconds 24 further cross hairs appear Repeat the process Performing graphics test The quality of the linearisation can be tested with a graphics program Under the tab die W...

Page 15: ...deactivated Activating write protection Right click on the Write protection symbol in the menu bar or press and hold the write protection with a single finger Select Activate write protection Press OK...

Page 16: ...could trigger a security warning Confirm the warning with No longer block Allow access Activate write protection Installing the QuadClient The installation file for the QuadClient is located in the H...

Page 17: ...prox 15 minutes The operating system is reset to the state of delivery Gira Control 19 Client USB connections i Note The operating system can be damaged if the Gira Control 19 Client no longer loads t...

Page 18: ...to 1 using the key Press the F10 key and confirm by pressing Enter Brief overview of the work steps described above in the BIOS Select Advanced BIOS features Select Hard Disk Boot Priority Select USB...

Page 19: ...0 C to 40 C Storage transport temperature 20 C to 60 C Relative humidity 10 to 85 r H no condensation Protection type IP20 System Processor type Intel AtomTM N270 Processor cycle 1 6 GHz L2 cache 512...

Page 20: ...trade installation company specialist electrical trade They will forward the devices to the Gira Service Center Gira Giersiepen GmbH Co KG Dahlienstrasse 12 42477 Radevormwald Germany USB USB version...

Page 21: ...H Co KG Elektro Installations Systeme Industriegebiet Mermbach Dahlienstra e 42477 Radevormwald Postfach 12 20 42461 Radevormwald Deutschland Tel 49 0 21 95 602 0 Fax 49 0 21 95 602 191 www gira de in...

Reviews: