background image

System 3000

Blind timer and timer BT, Operating top unit BT

(2)

Cover frame

(3a) Blind/shutter up / light on, brighter
(3b) Blind/shutter down / light off, darker
(4a) Disabling function
(4b) Activate Bluetooth coupling, 

Activating / deactivating automatic oper-
ation

(5)

Function LED

(6)

Status LED

LED display

Green

Blind/shutter activated / light switched on

Red

Disabling function active

Triple red flashing

Cover was previously connected to another insert

Orange

Automatic operation deactivated (only 2-gang cover)

Blue

Bluetooth connection active

Blue flashing

Bluetooth coupling mode active

Quick blue flashing

Device update is being performed

Triple blue flashing

Time is not set

Priorities for the LED display: 
- Red LED before green or orange LED 
- Blue LED before red LED

3

Intended use

Manual and time-controlled operation of e.g. Venetian blinds, shutters, awnings, lighting
or fans

Operation and programming with mobile end device (smartphone or tablet) via Bluetooth
with app

Operation of switching, dimming or Venetian blind insert, 3-wire extension or DALI Power
control unit of System 3000

Default setting

Switching times on a Venetian blind insert:

ƞ

 07:00, Mo - Thu

Ɵ

 21:00, Mo - Thu

ƞ

 07:00, Fr

Ɵ

 21:30, Fr

ƞ

 09:00, Sat

Ɵ

 21:30, Sat

ƞ

 09:00, Sun

Ɵ

 21:00, Sun

Astro function is deactivated

Automatic summer/winter time changeover is active

No switching times are available when operating on a switching/dimming insert.

Behaviour after a mains voltage failure

Voltage failure less than power reserve

All data and settings are preserved

Missed switching times are not performed later

Voltage failure greater than power reserve

2 / 12

32598122

10868257

06.07.2022

Summary of Contents for 5367 Series

Page 1: ...njuries fire or property damage possible Please read and follow manual fully Danger of electric shock Always disconnect before carrying out work on the device or load In so doing take all the circuit...

Page 2: ...e green or orange LED Blue LED before red LED 3 Intended use Manual and time controlled operation of e g Venetian blinds shutters awnings lighting or fans Operation and programming with mobile end dev...

Page 3: ...at sunrise and or before sunset Astro function Astro time through position fixing Astro time shift can be set for each switching time Automatic summer winter time changeover can be switched off Call f...

Page 4: ...in the ventilation position when moving down see Saving the ventilation position When executing via a Bluetooth wall transmitter the blind shutter is activated as long as pressure is applied to the b...

Page 5: ...r temperature After a further double click the device switches back to normal operation and signals this with a short switching off and on again After one minute without operation the device also retu...

Page 6: ...tention if required A call can be triggered via a 2 wire extension Bluetooth wall transmitter or push button Precondition The call function has been activated via the app Press the button of the exten...

Page 7: ...d consumer is obligated to return the device 11 Parameter list Adjustable parameters via app Depending on the insert the following parameters can be changed with the app Settings for switching dimming...

Page 8: ...tion if required If the function is activated a call can be triggered via a 2 wire extension Bluetooth wall transmitter or push button If a call has been triggered the lighting flashes 1 second on 1 s...

Page 9: ...ters Setting options Default setting Explanations Activating switch on delay for output 2 On Off Default setting On Switches the switch on delay for output 2 on and off If the parameter is switched of...

Page 10: ...ss sensor Input MAC address After entering the MAC address the received brightness for the controller is used by bright ness dependent switching operations Brightness evalu ation On Off Default settin...

Page 11: ...necessary for this func tion Action at dawn Depending on the insert used Switching dimming or moving the blind shutter The set value is called up when the twilight threshold value is exceeded E g the...

Page 12: ...a Giersiepen GmbH Co KG Elektro Installations Systeme Industriegebiet Mermbach Dahlienstra e 42477 Radevormwald Postfach 12 20 42461 Radevormwald Deutschland Tel 49 0 21 95 602 0 Fax 49 0 21 95 602 19...

Reviews: