Connecting up energy profile

Earth connection

Energy profiles with lighting elements and 
energy profiles which contain devices powered 
by 230 V must be earthed. The energy profiles 
have the following earth terminals:

• The lighting element is earthed via the terminal 

in the conduit box. The lighting element is also 
connected to the profile.

• An earth cable extends down to the profile 

base. Connect this cable to the profile base.

• If devices powered by 230 V are inserted into 

the empty units, the power profile must also be 
earthed. An additional earth terminal is 
available for this near the device unit. Connect 
this to the earth cable of the 230 V device.

Device connection

Due to the variability of the energy profile, all 
flush-mounted devices from the TX_44 or 
System 55 switch design range can be 
integrated. For this reason, please refer to the 
respective operating instructions accompanying 
each device for information on how each device 
is connected.

Lighting element connection

The lighting element of the energy profile is 
already pre-wired up to the connection terminal.
Proceed as follows to connect the lighting 
element:
1. Remove the connection box from the lower 

opening of the energy profile and open it.

2. Connect the lighting element via the  /N/  

terminals.

The available terminals can be used for the 
wiring of the empty units.

3. Close the connection box and push it back 

into the energy profile.

Installing/replacing light

Light sources with E27 treading of the energy 
efficiency classes A++ to E can be used.
To install or replace the light, proceed as follows:
1. Loosen both cover screws and remove the 

profile cover.

2. Pull the diffusing plate upward from the 

guide.

3. Insert the light.
4. Reinsert the diffusing plate from above 

(please note the "TOP FRONT" labelling).

5. Set the profile cover in place and fasten it 

with both cover screws.

L N

i

Light diameter

Lamps with a base diameter of up to 52 mm can 
be used in the Energy Profile.
If a slats element is used, the maximum base 
diameter is reduced to 48 mm!

Summary of Contents for 1345 26

Page 1: ...g Instructions Energy profile with three empty units height 491 mm 1345 26 28 Energy profile with lighting element and three empty units height 769 mm 1349 26 28 Energy profile with six empty units height 769 mm 1351 26 28 ...

Page 2: ... e g in an entrance area The Gira energy profile is available in different versions in the colours anthracite and aluminium Examples Energy profile with three empty units height 491 mm Order No 1345 26 28 Energy profile with lighting element and three empty units height 769 mm Order No 1349 26 28 Energy profile with six empty units height 769 mm Order No 1351 26 28 Device presentation Here the ene...

Page 3: ...n bolt 5 Guide the cables into the accompanying conduit boxes and connect the plastic sheathed cables which reach the device units 6 Connect the lighting element if present see Page 5 7 Connect the earth cable of the energy profile to the earth terminal of the profile base 8 Place the energy profile on the profile base and fasten it with the three Allen bolts M6 x 14 9 For energy profiles with a l...

Page 4: ... Fit the inserts with the accompanying sealing pans The profile has markings to which the supporting rings of the device can be aligned This ensures that the frames are inserted later on in such a way which ensures splash resistance 4 Set down the bottom section of the TX_44 frame and fasten it with the accompanying Phillips head screws B 3 5 x 16 5 Fit the central inserts and screw them down if n...

Page 5: ...e for information on how each device is connected Lighting element connection The lighting element of the energy profile is already pre wired up to the connection terminal Proceed as follows to connect the lighting element 1 Remove the connection box from the lower opening of the energy profile and open it 2 Connect the lighting element via the N terminals The available terminals can be used for t...

Page 6: ... g for path illumination 5 Set the profile cover in place and fasten it with both cover screws Technical data Dimensions W x H x D Profile base 229 x 10 x 155 mm Profile 142 x 491 x 75 mm or 142 x 769 x 75 mm Protection type IP 44 with closed device covers Connections terminal screws 1 x 4 mm2 or 2 x 2 5 mm2 Lamp Light sources with E27 treading of the energy efficiency classes A to E Power 21 W ma...

Page 7: ...rements via the specialist trade Please submit or send faulty devices postage paid together with an error description to your responsible salesperson specialist trade installation company electrical specialist trade They will forward the devices to the Gira Service Center ...

Page 8: ...Co KG Electrical installation systems Industriegebiet Mermbach Dahlienstraße 42477 Radevormwald P O Box 12 20 42461 Radevormwald Germany Phone 49 0 2195 602 0 Fax 49 0 2195 602 191 www gira com info gira com 10866543 49 19 ...

Reviews: