4
Screwing down directly
The energy profile can be set up directly on the
ground on a solid base, e.g. a cement or asphalt
surface.
.
1. Drill a hole at the intended mounting location
and insert the accompanying plug.
2. Guide the cables through the profile base and
mount the base to the ground with the
accompanying hexagon bolt.
3. Guide the cables into the accompanying
conduit boxes and connect the plastic-
sheathed cables which reach the device
units.
4. Connect the lighting element (if present) (see
5. Connect the earth cable of the energy profile
to the earth terminal of the profile base.
6. Place the energy profile on the profile base
and fasten it with the three Allen bolts
(M6 x 14).
7. For energy profiles with a lighting element,
insert the light and close the profile with the
cover.
Outfitting available device units
The empty units of the energy profiles can be
outfitted with components from the TX_44 or
System 55 switch design ranges.
Please install the flush-mounted inserts as
follows:
1. Connect the device inserts.
2. Lay the connection lines in the conduit boxes.
3. Fit the inserts with the accompanying sealing
pans. The profile has markings to which the
supporting rings of the device can be aligned.
This ensures that the frames are inserted later
on in such a way which ensures splash
resistance.
4. Set down the bottom section of the TX_44
frame and fasten it with the accompanying
Phillips-head screws (B 3.5 x 16).
5. Fit the central inserts and screw them down if
necessary.
6. Attach the adapter plates with a hinged cover
if necessary.
7. Clip on the cover plate of the frame and press
in the Torx screws.
i
Profile with no lighting element
For profiles with no lighting element, all devices
and TX_44 cover frames must be mounted
before the profile cover is set in place. To keep
the profile splash-resistant, the top edge of the
TX_44 cover frame must be flush with the top
edge of the profile.
i
Installation suggestion
Prepare the energy profile in your workshop:
Install the devices and lay the corresponding
plastic-sheathed cables in the conduit boxes.
Then only the conduit boxes need be wired up
on site.
i
Integration of System 55 inserts
Inserts from System 55 must be installed via a
TX_44 adapter plate with a hinged cover. An
overview of the inserts which can be combined
with each adapter plate is found in the current
Gira catalogue.