Installation/Mounting Instructions

Energy profile with three empty units,
height: 491 mm

1345 26/28

Energy profile with lighting element and three empty units,
height: 769 mm

1349 26/28

Energy profile with six empty units,
height: 769 mm

1351 26/28

Summary of Contents for 1345 26

Page 1: ...g Instructions Energy profile with three empty units height 491 mm 1345 26 28 Energy profile with lighting element and three empty units height 769 mm 1349 26 28 Energy profile with six empty units height 769 mm 1351 26 28 ...

Page 2: ... e g in an entrance area The Gira energy profile is available in different versions in the colours anthracite and aluminium Examples Energy profile with three empty units height 491 mm Order No 1345 26 28 Energy profile with lighting element and three empty units height 769 mm Order No 1349 26 28 Energy profile with six empty units height 769 mm Order No 1351 26 28 Device presentation Here the ene...

Page 3: ...n bolt 5 Guide the cables into the accompanying conduit boxes and connect the plastic sheathed cables which reach the device units 6 Connect the lighting element if present see Page 5 7 Connect the earth cable of the energy profile to the earth terminal of the profile base 8 Place the energy profile on the profile base and fasten it with the three Allen bolts M6 x 14 9 For energy profiles with a l...

Page 4: ... Fit the inserts with the accompanying sealing pans The profile has markings to which the supporting rings of the device can be aligned This ensures that the frames are inserted later on in such a way which ensures splash resistance 4 Set down the bottom section of the TX_44 frame and fasten it with the accompanying Phillips head screws B 3 5 x 16 5 Fit the central inserts and screw them down if n...

Page 5: ...e for information on how each device is connected Lighting element connection The lighting element of the energy profile is already pre wired up to the connection terminal Proceed as follows to connect the lighting element 1 Remove the connection box from the lower opening of the energy profile and open it 2 Connect the lighting element via the N terminals The available terminals can be used for t...

Page 6: ... g for path illumination 5 Set the profile cover in place and fasten it with both cover screws Technical data Dimensions W x H x D Profile base 229 x 10 x 155 mm Profile 142 x 491 x 75 mm or 142 x 769 x 75 mm Protection type IP 44 with closed device covers Connections terminal screws 1 x 4 mm2 or 2 x 2 5 mm2 Lamp Light sources with E27 treading of the energy efficiency classes A to E Power 21 W ma...

Page 7: ...rements via the specialist trade Please submit or send faulty devices postage paid together with an error description to your responsible salesperson specialist trade installation company electrical specialist trade They will forward the devices to the Gira Service Center ...

Page 8: ...Co KG Electrical installation systems Industriegebiet Mermbach Dahlienstraße 42477 Radevormwald P O Box 12 20 42461 Radevormwald Germany Phone 49 0 2195 602 0 Fax 49 0 2195 602 191 www gira com info gira com 10866543 49 19 ...