b.
alternatively, press “mem” button in
Clock mode to display the stored results. the current
memory bank will blink and the amount of results in
this bank will be displayed.
see picture 7-
1. press “start” button to change over
to other bank. see picture 7-2.
picture 7-2
picture 7-3
Confirm your selection by pressing “mem”
button. the current bank can also be confirmed
automatically after 5 seconds with no operation.
If no result stored, lCd will show dashes as
picture 7-3.
c.
after selecting the memory bank,
the lCd will display the average value of the last
three results in this bank, see picture 7-4 &7-5.
d. When the average is displayed, press the
“mem” button, the most recent result will be
displayed. see picture 7-6. followed by, the blood
pressure and pulse rate will be shown
separately, and irregular heartbeat symbol (if
any) will blink, see picture 7-6 &7-7&7-8. press
“mem” button again to review the next result,
see picture 7-9. In this way, repeatedly pressing
the “mem” button displays the respective results
measured previously. e. When displaying the
stored results, the monitor will turn off
automatically after 1 minute of no operation. you
can also press the button “start” to turn off the
monitor manually.
picture 7-4
picture 7-5
picture 7-6
picture 7-7
picture 7-8
picture 7-9
8. deleting measurements from the memory
When any result (except average reading of the last three
results) is displaying, keeping on pressing button “mem” for
three seconds, all results in the current memory bank will be
deleted after three “beep”. lCd will show picture 8, press the
button “mem” or “start”, the monitor will turn off.
picture 8
9. assessing high blood pressure for adults
the following guidelines for assessing high blood pressure (without regard to
age or gender) have been established by the World health organization
(Who). please note that other factors (e.g. diabetes, obesity, smoking, etc.)
need to be taken into consideration. Consult with your physician for accurate
assessment, and never change your treatment by yourself.
Classification of blood pressure for adults
Summary of Contents for KD-735
Page 86: ...PORTuGu S 86 flutua es de tens o emiss es intermitentes IeC 61000 3 3 n o aplic vel...
Page 128: ...128 3 00 1 1 5...
Page 129: ...129 lcd 2x 60 iec 60601 1 2005 en 60601 1 2006 ac 2010 1...
Page 131: ...131 18 lcd 1 2 5 3 4 5 6 1 1 5 300 mmhg 15 mmhg 3 7 1 2 a V 3 4 5 8 9 10...
Page 132: ...132 11 12 ihb 2 ihb 1 cV 25 2 014 53 13 14 15 16 15 fcc o...
Page 133: ...133 17 15 fcc 1 2 18 b ansi aami sP 10 2002 a1 2003 a2 2006 1 a b aaa c lcd...
Page 134: ...134 2 a lcd 2 2 1 2 2 1 2 2 b start mem 2 2 start mem mem c start d 1 e 3...
Page 135: ...135 4 a 1 2cm b lcd c 1 2 3 4 5 5 200 5 a b c 6 a...
Page 139: ...139...
Page 141: ...141 3 4 5 6 2 7 8 9 10 000 1 000 10 2 75 90 bf bf...
Page 146: ...146 GIMA 12 gima gima software gima...
Page 148: ...148 ARABIC...
Page 150: ...150 ARABIC...
Page 151: ...151 ARABIC...
Page 152: ...152 ARABIC...
Page 153: ...153 ARABIC...
Page 154: ...154 ARABIC battery...
Page 155: ...155 ARABIC...
Page 156: ...156 ARABIC...
Page 157: ...157 ARABIC...
Page 158: ...158 ARABIC 8...
Page 160: ...160 ARABIC...
Page 161: ...161 ARABIC...
Page 162: ...162 ARABIC...
Page 163: ...163 ARABIC...
Page 164: ...164 ARABIC...
Page 165: ...165 ARABIC...