Aerosol Mistral is a system for aerosol therapy, with 230V ~ / 50Hz power supply, intended 

for household use. 

The appliance is designed for non-continuous use (Ton: 20 mins / Toff: 40 mins).

The medical device is designed to be easy to transport and use and is indicated for nebu-

lizing bronchodilators and antibiotics. Made of plastic housing with high heat and electrical 

insulation in accordance with the European safety standards. 

GENERAL INSTRUCTIONS

• CAREFULLY READ THE MANUAL BEFORE USE

• FOR DRUG INHALATION ALWAYS FOLLOW MEDICAL ADVICE

• DO NOT DISASSEMBLE THE APPLIANCE. FOR ANY INTERVENTION, CONTACT THE 

TECHNICAL SERVICE OF THE DISTRIBUTOR AND/OR GIMA’s TECHNICAL SERVICE

• REMOVE THE APPLIANCE FROM THE TRANSPORT BAG BEFORE EACH USE

BASIC SAFETY STANDARDS

1.  When opening the packaging, check the integrity of the appliance by paying particular at-

tention to the presence of damage to plastic components which may disclose internal live 

parts of the appliance and to breakage and/or stripping of the power cable. 

In this case, 

do not connect the plug to the socket. Carry out these operations before each use.

2.  Before connecting the appliance, always check that the electrical data indicated on the 

label and the type of plug used correspond with the data of the power network to which 

it is intended to be connected.

3.  Do not leave the appliance plugged unnecessarily: disconnect the plug from the power 

network if not used. 

4.  Comply with the safety standards for electrical appliances. In particular:

- Use only original accessories and components supplied by Gima S.p.A. in order to 

ensure utmost efficiency and security of the device.

-  Never immerse the appliance in water. 

-  Place the appliance on flat and stable surfaces in order to avoid obstructing the cool-

ing openings located on its sides.

-  Do not use the appliance in environments with the presence of flammable anesthetic 

mixture with air, oxygen, or nitrous oxide.

-  Do not use the appliance with anesthetic and respiratory equipment.

-  Avoid touching the appliance with wet hands.

-  The use of this appliance by children and/or people with disabilities shall be closely 

monitored by an adult with full mental capacity.

-  Disconnect the appliance from the power supply if not used.

-  Do not pull the power cable to disconnect the plug. Grab the plug with the fingers to 

pull it out from the power network. 

- Store and use the appliance in environments protected by atmospheric agents and 

away from heat sources. After each use, it is recommended to store the device inside 

its box away from dust and direct sunlight.

-  In general, it is not recommended to use simple or multiple adapters and/or extension 

cables. If their use is essential, it is necessary to use devices in compliance with the 

safety standards, paying attention not to exceed the maximum power limits indicated 

ENGLISH

Summary of Contents for 28102

Page 1: ...the product AVIS Les op rateurs doivent lire et bien comprendre ce manuel avant d utiliser le produit ACHTUNG Die Bediener m ssen vorher dieses Handbuch gelesen und verstanden haben bevor sie das Pro...

Page 2: ...nected 3 Do not leave the appliance plugged unnecessarily disconnect the plug from the power network if not used 4 Comply with the safety standards for electrical appliances In particular Use only ori...

Page 3: ...people with disabilities 10 Do not leave the device unattended in areas accessible to minors and or people with limited mental capacity as they may be strangled with the air hose 11 The patient can c...

Page 4: ...to any of its part due to accident misuse and or abuse Any unauthorized intervention on the device even the slightest one will imme diately invalidate the warranty and does not ensure the compliance w...

Page 5: ...detergents Do not use excessively wet cloths as the contact of liquids with the electri cal parts of the appliance may cause malfunctions or may be hazardous While cleaning the device make sure that n...

Page 6: ...ntact the reseller or Gima s technical service BEFORE CARRYING OUT ANY CHECKS IN THE EVENT OF ANOMALIES OR MALFUNCTIONS CONTACT GIMA S TECHNICAL SERVICE THE MANUFACTURER OFFERS NO GUARANTEE FOR THE AP...

Page 7: ...WASHING Where diseases with risk of infection and microbial contamination are present the end user shall carry out the washing operations properly The washing procedure can be performed only if the co...

Page 8: ...or if the device is no longer efficient If the filter is too dirty it shall be replaced AIR FILTER REPLACEMENT The air filter shall be replaced every 25 hours of operation or when it is too dirty For...

Page 9: ...e nebulizer facing upwards in order to prevent any substances and or the medicine from leaking out of the nebulizer during normal use In the event of overfilling empty the ampoule clean it and repeat...

Page 10: ...e electromagnetic environment Radiated emissions Conductions CISPR11 Group 1 The Mistral aerosol uses RF energy only for Internal function Therefore its RF emissions are very low and do not cause any...

Page 11: ...ower of the transmitter in Watt W according to the manufacturer of the transmitter and d is the recommended separation distance calculated in meters m The field strengths from fixed RF trans mitters a...

Page 12: ...eparation distances between portable and mobile radio communi cation appliances and the monitor The Mistral aerosol is designed to operate in an electromagnetic environment in which the RF radiated in...

Page 13: ...expenses and packaging not included All components subject to wear are not included in the warranty The repair or replacement performed during the warranty period shall not extend the warranty The wa...

Reviews: