Immunity test

Electrostatic 

discharge (ESD)

IEC 61000-4-2

Electrical fast 

transient/burst

IEC 61000-4-5

Surge

IEC 61000-4-5

Voltage dips,short 

interruptions and 

voltage variations 

on power supply input 

lines

IEC 61000-4-11

Power frequency 

(50/60 HZ) magnetic 

field

IEC 61000-4-8

IEC 60601

Test level

±2 KV contact

±4 KV contact

±6 KV contact

±2 KV air

±4 KV air

±8 KV air

±2 KV for power 

supply lines

 ±1 KV 

differential mode

±2 KV common 

mode

<5% U

T

(>95% dip in U

T

for 0,5 cycle

40% U

T

(60% dip in U

T

for cycle

70% U

T

(30% dip in U

T

for cycle

<5% U

T

(>95% dip in UT) 

for 5 s  

3A/m

Electromagnetic environment 

guidance

Floor should be wood, concrete 

or ceramic tile. If floors are covered  

with synthetic material, the relative 

humidity should be at less 30% 

Mains power quality should be 

that of a typical commercial 

or hospital environment

Mains power quality should be 

that of a typical commercial 

or hospital environment

Mains power quality should be 

that of a typical commercial 

or hospital environment. 

If the user of  27363 requires 

continued operation during 

power mains interruptions,

it is reccomended that the 27363 

be powered from an uninterruptible 

power supply or a battery. 

Power frequency magnetic 

field should beat levels 

characteristic of a typical 

location in a typical commercial 

or hospital environment.

GUIDANCE AND MANUFACTURER’S DECLARATION – ELECTROMAGNETIC IMMUNITY

The equipment 

27363

 is intended for use in the electromagnetic environment specified below. 

The customer or the user of the equipment 

27363

 should assure that it is used in such an environment

Compliance

level

±2 KV contact

±4 KV contact

±6 KV contact

±2 KV air 

±4 KV air

±8 KV air

±2 KV for power 

supply lines

±1 KV 

differential mode

±2 KV common 

mode 

<5% U

T

(>95% dip in U

T

for 0,5 cycle

40% U

T

(60%dip in U

T

for cycle

70% UT

(30% dip in U

T

for cycle

<5% U

T

(>95% dip 

in U

T

) for 5 s

3A/m

Summary of Contents for 27363

Page 1: ...efore using the product AVIS Les op rateurs doivent lire et bien comprendre ce manuel avant d utiliser le produit ATENCI N Los operadores tienen que leer y entender completamente este manual antes de...

Page 2: ...ence norms 17 1 5 Electrical features and voltage 18 1 6 Components identification 18 Electrical schema 19 1 7 General safety warning 19 Chapter 2 INSTALLATION 20 2 1 Transport and stocking 20 2 2 Con...

Page 3: ...USAGE MAINTENANCE Instructions for a correct installation are contained in the par 2 2 CONDITIONS FOR THE INSTALLATION Follow the instructions for use Read carefully this manual for the installation...

Page 4: ...an discover variations of colour intensity on the foot plant corresponding to higher or lower plant pressure The base is of ABS A separable net cable with plug a jack and a led strip are its electric...

Page 5: ...sports centres by operators with knowledge of biomechanics like doctors in sport medicine orthopedic specialists and physiotherapists Reference harmonized norms CEI EN 60601 1 Safety of electromedical...

Page 6: ...assembled and fixed in such a solid way so as to stand up to the often adverse transport conditions As to indirect shocks the device is classified in Class II As to current leakage it can be classifi...

Page 7: ...always take the following precautions A Always unplug the podoscope during maintenance operations B Do not move the podoscope while using it C Each time before the usage check the functioning of the c...

Page 8: ...ystyrene polyethylene cardboard must follow your local waste disposal guidelines 3 Verify that the podoscope has not been damaged during transport In case please contact the manufacturer immediately I...

Page 9: ...00 3 2 Voltage fluctuations flicker emissions IEC 61000 3 3 Compliance Group1 Class B Compliant Compliant Electromagnetic environment guidance The equipment 27363 must emit electromagnetic energy in o...

Page 10: ...ment Mains power quality should be that of a typical commercial or hospital environment Mains power quality should be that of a typical commercial or hospital environment If the user of 27363 requires...

Page 11: ...the examination can be performed only if the patient is barefoot otherwise lay the caoutchouc on the transparent surface This material is also useful to check the validity of arch support treatments W...

Page 12: ...19 Then get out the blown fuse with a suitable instrument and replace it with a T 0 5 A 5x20 250V fuse If you have to replace the power cord the new one must have the same characteristics and certifi...

Page 13: ...he warranty GIMA will repair and or replace free of charge all the defected parts due to production reasons Labor costs and personnel traveling expenses and packaging not included All components subje...

Page 14: ...74...

Page 15: ...75...

Page 16: ......

Reviews: