background image

7

MyPIPETMAN®

 

|

 QUICK GUIDE

QUICK GUIDE

 

| MyPIPETMAN®

 

NOTE

To ensure good performance, always lock 

the pipette before pipetting by selecting 

the locking icon.  

3

2

1

Figure 5

Tip ejector dual 

position adapter 

and extension for 

P2L and P10L

Short collar 

tips

Long collar 

tips

180°

Fitting the Tip Ejector Adapter 

Single Channel Models

A

 For P2 and P10 pipettes equipped with a

 

stainless-steel tip ejector,

 a dual-position 

adapter is required to fit and eject DL10 tips 

(long tips) and D10 tips (short tips).

To fit the adapter for short and long tips 

(refer to Figure 5): 

1. 

Pull the adapter down from the 
stainless steel tip ejector. 

2. 

Turn the adapter 180°. 

3. 

Refit the adapter so that the end of the 
stainless steel tip ejector engages the 
shorter or longer slot of the adapter. 

B

 For P2 and P10 pipettes equipped 

with a 

plastic tip ejector, 

a dual-position adapter  

is required to fit and eject D10 tips (short 

tips).

To fit a tip ejector extension  
(refer to Figure 5):

1. 

Slide the extension over the tip holder.

2. 

Push the extension firmly onto the 
end of the tip ejector until it clicks into 
place.

 

To remove a tip ejector extension:

1. 

Gently twist the adapter.

2. 

Pull it away from the pipette.

To fit

To remove

Secure Pipetting

After selecting your volume, turn the selector to the right until 

the cursor reaches the locking 

3

 for secure pipetting.

B

A

Summary of Contents for MyPipetman P10

Page 1: ...Quick Guide EN A U TOCLAVABL E FULLY...

Page 2: ...n the P2 and P10 models Bag of ten filters only for P5000 and P10mL models Certificate of Conformity Safety bag Multichannel Models MyPIPETMAN pipette Quick Guide Ejector spacer for D10 tips only for...

Page 3: ...AN single channel and multichannel model components Color coded push button Locking system Tip ejector button Color ring Connecting nut Tip ejector Ejector lock Ejector clip Tip holder Cover Single ch...

Page 4: ...with D200 Tips 20 100 200 0 50 0 80 1 60 0 20 0 25 0 30 2 5 0 8 0 8 1 0 0 25 0 15 1 6 1 6 1 6 0 6 0 6 0 6 8 0 1 6 0 8 3 0 0 6 0 3 MyPIPETMAN P1000 with D1000 Tips 100 500 1000 3 0 4 0 8 0 0 6 1 0 1 5...

Page 5: ...MyPIPETMAN P8x300 MyPIPETMAN P12x300 with D300 Tips 20 30 150 300 1 00 1 00 1 50 3 00 0 35 0 35 0 60 1 00 5 0 3 3 1 0 1 0 1 75 1 17 0 4 0 33 8 0 8 0 8 0 8 0 3 0 3 0 3 0 3 0 40 0 26 67 5 33 2 67 15 0...

Page 6: ...h button Light click volume selection position 1 Turn the selector until the cursor reaches the middle 2 2 Select the volume by turning the push button NOTE When selecting the volume you will hear cli...

Page 7: ...down from the stainless steel tip ejector 2 Turn the adapter 180 3 Refit the adapter so that the end of the stainless steel tip ejector engages the shorter or longer slot of the adapter B For P2 and P...

Page 8: ...Channel Models P2 P10 D10 DL10 DF10ST DFL10ST P20 D200 DF30ST P100 D200 DF100ST P200 D200 D300 DF200ST DF300ST P1000 D1000 D1200 DF1000ST DF1200ST P5000 D5000 P10mL D10mL 4 1 2 3 Multichannel Models...

Page 9: ...e tips for the best pipetting performance Ideally the pre wet includes both immersing the tip in the liquid and performing one pipetting step Pre wetting the tips helps ensure that volumes that you pi...

Page 10: ...e the push button smoothly Eject the tip by pressing firmly on the tip ejector button Second stop First stop Aspirate Dispense Prepare Purge Home Rest Position Ejecting the Tips To avoid touching used...

Page 11: ...r handling spillage or exposure to any corrosive environment abuse misuse or misapplication or from ordinary wear and tear including seal and O rings This warranty shall also be void in the event pipe...

Page 12: ...LT801608 A 2019 Gilson Inc All rights reserved gilson com contactus LT801608 B 2022 Gilson Inc All rights reserved...

Reviews: