- 3 -

User's GUide

EN

optional Accessories

•  Pedal for TrACKMAN  

   

ref. F70261

•  0.5 mL, 1.5 mL and 2 mL Microtube Holder 

   (vessel capacity: 16 microtubes) 

ref. F70105 

The Microtube Holder allows for placing 0.5 mL tubes into one 

side and 1.5 mL or 2.0 mL tubes into the other side, thus enabling 

use of the TrACKMAN to track pipetting between microtubes. 

The TrACKMAN can be used with any kind of pipette (mechanical or electronic, single, multichannel 

and repetitive). The following is a list of Gilson pipettes:
•  PiPeTMAN® 

•  PiPeTMAN Neo® 

•  PiPeTMAN Neo Multi

•  PiPeTMAN Concept® 

•  PiPeTMAN Concept Multi

•  disTriMAN® 

•  rePeTMAN® 

•  MiCrOMAN®

 
For ordering information please contact your Gilson distributor or http://www.gilson.com.

SAFEtY notES  

Possible dangers if the safety precautions are not observed

The TrACKMAN is a state-of-the-art instrument and is safe to use. All persons working with the TrACKMAN 

must read the operating and safety instructions before operating the instrument.

Safety at work

in addition to any safety precautions listed here, all other relevant safety aspects–e.g., GLP, GMP, pro-

fessional trade associations, department of Health, trade supervisory authorities–must be observed.

The  TrACKMAN  has 

an  iP  32  rating.  it  is 

protected  against 

direct sprays of water 

up  to  15°  from  the 

vertical.

For more information, 

refer to Chapter 7.

changes in configuration/design by user

No changes may be made to the TrACKMAN. 

Any parts that become defective must be 

replaced by original Gilson parts.

Cautions:
Do not autoclave the TRACKMAN. Extreme 

heat will damage electronic components.
Do not immerse the TRACKMAN; liquid inside 

can damage its internal components.
Do not clean the keypad with bleach solu-

tions  or  other  solvents.  Caustic  cleaning 

solutions can damage the keypad.
Do not use the TRACKMAN in a potentially 

explosive environment or with potentially 

explosive chemicals.  

Figure 1 

Figure 2 

Summary of Contents for F70301

Page 1: ...User s Guide...

Page 2: ...ofessional assistant who keeps track of pipetting from microtube to microtube and from microplate to microplate The TRACKMAN is ideal for tracking pipetting It holds two microplates 96 well or 384 wel...

Page 3: ...AllpersonsworkingwiththeTRACKMAN must read the operating and safety instructions before operating the instrument Safety at work In addition to any safety precautions listed here all other relevant sa...

Page 4: ...organiza tiontocollectandrecycletheproducts 4 DESCRIPTION TRACKMAN Location A Location B LED light box Position indicators for 96 or 384 well microplates Plate holder for 96 or 384 well microplates F...

Page 5: ...ure 5 Retractable stand Reset In case of malfunction first reset the TRACKMAN To reset insert a paper clip into the reset hole on the rear panel of the TRACKMAN for at least 3 sec Figure 6 Cable Guide...

Page 6: ...nfig to set up a run Setup to set sound timer and transport function Modify appears when Config or Setup are chosen modification can be done Valid to accept the selection Quit to return to the Operati...

Page 7: ...TheTRACKMANisprovidedwithaminimalbatterycharge Before using a new TRACKMAN it is recommended to fully charge the battery TheTRACKMAN battery has been designed to ensure up to 8 hours of cordless opera...

Page 8: ...ds to be used in connected mode Sleep Mode TheTRACKMAN goes into sleep mode and the display will shut off after five minutes ofinactivity PressON OFFtoreactivatethe TRACKMAN thelastprogramandposition...

Page 9: ...o microplates A B 96 well or 384 well a sequence of microtubes or microplates A B tube 0 5 mL tube 1 5 mL or 2 0 mL 96 well or 384 well Overview of all programming possibilities microplate microtubes...

Page 10: ...without a risk of pipetting error If you want to continue your run press No this will cancel the stop function If you confirm the option by selecting Yes you will reset the run How to use the TRACKMA...

Page 11: ...If you choose Yes the run starts if you choose No you will return to the previous menu 9 The pattern will light automatically to track your pipetting 10 When the run is finished the first screen appea...

Page 12: ...es may be used To rinse wipe the TRACKMAN with a soft cloth or lint free tissue dipped in distilled water Allowittoairdryordryitcarefullywith a soft cloth or lint free tissue If you use chemical solut...

Page 13: ...display Recharge battery 7 Reset the software 5 No operation possible Recharge battery 7 Reset the software 5 Step touch pads do not work Set program to Manual mode 10 Lift finger between clicks 10 N...

Page 14: ...European Directives Villiers le Bel October 1st 2009 GILSON S A S 19 avenue des Entrepreneurs BP 145 95400 VILLIERS LE BEL FRANCE Tel 33 0 1 34 29 50 00 Fax 33 0 1 34 29 50 20 TRACKMAN 2004 108 EC Ele...

Page 15: ...ide by side transparent and translucent AC Adapter Input 100 240V 0 4A 47 63Hz Output 5Vdc 2 0A Indoor use only Battery Gilson Lithium Polymer Cell Battery Rating 3 7V 1Ah 3 7 Wh autonomy up to 8 hour...

Page 16: ...d Gilson Inc World Headquarters 3000 Parmenter Street I P O Box 620027 I Middleton WI 53562 0027 USA Tel 1 800 445 7661 or 1 608 836 1551 I Fax 1 608 831 4451 Gilson S A S 19 avenue des Entrepreneurs...

Reviews: