WindSonic Doc No 1405 PS 0019 Issue 28 November 2019
51
Bx - Baud rate
Item
Options
Command
Baud rate
2400
4800
9600
19200
38400
B1
B2
B3
B4
B5
To change the Baud rate when using HyperTerminal: -
E.g. If set to B3 (9600 baud) and it is required to set to Baud rate to B2 (4800 baud).
Type * to enter Configuration Mode.
Type B 2 and press ENTER,
(Do not type any further commands at this stage).
Close the 9600 Baud HyperTerminal connection.
Open HyperTerminal and set the new connection Baud Rate to 4800 baud.
Type B and press ENTER, the letter B will be shown followed by Capitol B2
Type Q and press ENTER, data will scroll at the new baud rate.
Cx - Analogue settings
The following command is only valid for the WindSonic Option 3:
Item
Options
Command
Analogue Wraparound
(Chart recorder facility)
Wrap around
0 – 539
Normal
0 - 359
C1
C2
Dx - Diagnostic and Configuration Command (See Section 10.8)
Ex - Communications Protocol
Item
Options
Command
Communications protocol
RS422 / RS485 (point to point)
RS232
E2
E3
To change settings refer to Connecting to a PC (Para’s 7.5 and 7.6).
Option 1 unit default setting will be E3
Option 2 and 3 unit default setting will be E2