GMX200 ASCII factory default configuration settings
Default configuration settings
Setting
Function
Comms Levels
RS232
Baud Rate
19200
Data Connection
Data Bits 8, Parity None, Stop Bits 1, Flow Control
None.
Node ID
Q
Output rate
1Hz
Message Mode
Continuous
ASCII Set Up
Carriage return and line feed, Echo on
North Alignment
0
Sensor WindSpeed
On
Wind Speed Units
MS (Metres/Second)
Report Format
Node, Polar (Relative Wind Direction and relative Wind
Speed), Corrected Wind Direction, Date and Time,
Supply Voltage, Status, Checksum.
Status Message Output On
Report Message
Output
On
Units Message Output
On
Inputs Message Output
On
Output Sentence
Comma Separated Variable