23
Model: FSH-5 & FSH-6
Overview
3.02
Filter Chamber & Exhaust
Item
Description
Function
1
Hood Filter Door (2)
Provides access the Pre-Filter, E.A.C. and Charcoal Filters. Both
Doors must be closed and latched before the Hood will operate.
2
Baffle Filter (2)
The first stage of the ventless air cleaning system. Stainless steel
filters capture larger grease particulate. Easily to remove for daily
cleaning.
The Baffle Filters should be cleaned daily
.
3
Pre-Filter (2)
Single-use, disposable filters remove moisture and some additional
grease-laden vapor from the air stream. Help to keep the E.A.C. Cells
performing effectively.
NEVER attempt to clean and re-use Pre-
Filters ... Replace every 7-10 days with NEW
.
4
E.A.C. Filter Cells (2)
(Left & Right)
E.A.C. Collector Cells are sustainable electrostatic devices that
capture fine particulate from grease-laden vapor and smoke
generated by the cooking appliances on plates in the cell.
To
maintain peak performance, E.A.C. Cells must be cleaned DAILy as
described later in this Manual.
5
Charcoal Filter (2)
Single-use, disposable filters that help to control cooking aromas in
exhausted air. Filters must be replaced periodically.
NEVER attempt
to clean and re-use Charcoal Filters ... Typically, replace with NEW
filters every 30 to 45 days. Replacement cycle is dependent on
appliance types in use, and types/quantities of foods being cooked.
6
Hood Side Skirts &
Backsplash
Sides Skirt helps contain vapors produced by cooking appliances
and facilitate Hood capture. A Backsplash helps protect walls.
These components must be used.
The self-supporting Floor Stand model does not utilize these
components.
7
Exhaust Outlet
Directs cleaned air back into the room.
A minimum clearance of
14” MUST be maintained between the top of the Exhaust Outlet
and the ceiling, or other obstruction
.
DO NOT attempt to direct exhaust into a different space by
attaching any type of duct extension to the outlet; will cause
poor performance.
8
Grease Drip Cup
Catches and collects grease condensate generated at the Baffle
Filters. This cup should be emptied and cleaned daily.
9
E.A.C. Drip Pan (2)
Catches and collects grease residue which may drip from E.A.C.
Filter Cells between cleanings. Should be checked/emptied and
daily, clean as needed.
* Not shown
Summary of Contents for FSH-5
Page 2: ......
Page 4: ......
Page 30: ...Model FSH 5 FSH 6 Overview 20 5 2 1 ILS Option Only 3 4 3 01 Control Panel ...
Page 32: ...22 Model FSH 5 FSH 6 Overview 3 02 Filter Chamber Exhaust Not shown 2 7 8 1 5 3 4 6 9 9 ...
Page 36: ...26 Model FSH 3 5 FSH 4 Overview ...
Page 50: ...40 Model FSH 5 FSH 6 Operation Filter Maintenance ...
Page 62: ...52 Model FSH 5 FSH 6 Parts List Not shown 7 04 Under Hood Filters Lights 4 5 2 1 3 1 3 ...