7
Model: FSH-5 & FSH-6
Installation
1. Use 1/2” All-Thread, cut to appropriate lengths, to hang Hood using hex nuts and washers as shown above.
Ensure the hood is level, left to right and front to back; adjust hex nuts at mounting brackets to obtain
levelness.
2. After leveling, securely tighten the nuts.
3. In order for the Hood to perform properly as designed to effectively capture the grease-laden vapors generated
by cooking appliances, the provided Backsplash and Side Skirts must be installed on the Hood, see
Section
2.03.2, Hood Skirt Installation
.
69”
to
78”
Flo
or
to
Skirt
2.03.1 Mounting Detail - Ceiling Suspended
NOTE:
All mounting hardware and installation labor is to provided by the Purchaser. This expense is not included
with Hood purchase.
Hood is typically suspended from ceiling joists using 1/2” All-Thread Rod and suitable beam clamps, or other
appropriate structure. All-Thread is attached to Hood at the four (4) welded suspension Brackets on each corner
of the top, as shown below.
Before continuing, have the ceiling structure inspected to verify that it is substantial enough to support the weight
of the Hood; see
Section 1.04.4, Weights
.
1/2” All-Thread
1/2” Hex Nut
1/2” Lock Washer
1/2” Flat Washer
1/2” Hex Nut
1/2” Lock Washer
1/2” Flat Washer
Mounting Bracket
Summary of Contents for FSH-5
Page 2: ......
Page 4: ......
Page 30: ...Model FSH 5 FSH 6 Overview 20 5 2 1 ILS Option Only 3 4 3 01 Control Panel ...
Page 32: ...22 Model FSH 5 FSH 6 Overview 3 02 Filter Chamber Exhaust Not shown 2 7 8 1 5 3 4 6 9 9 ...
Page 36: ...26 Model FSH 3 5 FSH 4 Overview ...
Page 50: ...40 Model FSH 5 FSH 6 Operation Filter Maintenance ...
Page 62: ...52 Model FSH 5 FSH 6 Parts List Not shown 7 04 Under Hood Filters Lights 4 5 2 1 3 1 3 ...
Page 68: ...58 Model FSH 5 FSH 6 Parts List ...
Page 69: ......