OF THE TUBE.. IN THIS CASE, THE TENDENCY IS TO OB-
TAIN A REDUCED FUEL FLOW RATE. THE SUCTION OUT-
LET ON THE MANIFOLD HAS A SECTION INTENTIONALLY
REDUCED FOR THE PURPOSE OF ENHANCING THE SUC-
TION PULSATION AND THEREBY GUARANTEE A CON-
STANT TAP FLOW RATE.
Specific tooling
020329Y
MityVac vacuum-operated pump
Characteristic
Minimum flow rate
20 cc
- Completely empty the gas tank.
- Remove the petrol delivery tube and the suction
tube.
- Loosen the clip and remove the tap.
- Clean the tank and the filter of the tap with a spe-
cific solvent.
- Refit the tap making sure that there is an O-Ring.
- Turn the tap to the direction it had before it was
removed and block the clip.
N.B.
THE FILTER CAN BE UNSCREWED FROM THE COCK TO
FACILITATE CLEANING.
Engine
Stalker 50
ENG - 88
Summary of Contents for Stalker 50
Page 1: ...MANUALE STAZIONE DI SERVIZIO 638540 Stalker 50 ...
Page 4: ......
Page 6: ...INDEX OF TOPICS CHARACTERISTICS CHAR ...
Page 16: ...INDEX OF TOPICS TOOLING TOOL ...
Page 24: ...INDEX OF TOPICS MAINTENANCE MAIN ...
Page 32: ...INDEX OF TOPICS TROUBLESHOOTING TROUBL ...
Page 38: ...INDEX OF TOPICS ELECTRICAL SYSTEM ELE SYS ...
Page 55: ...INDEX OF TOPICS ENGINE FROM VEHICLE ENG VE ...
Page 57: ...Stalker 50 Engine from vehicle ENG VE 57 ...
Page 58: ...INDEX OF TOPICS ENGINE ENG ...
Page 89: ...INDEX OF TOPICS SUSPENSIONS SUSP ...
Page 98: ...INDEX OF TOPICS BRAKING SYSTEM BRAK SYS ...
Page 107: ...INDEX OF TOPICS CHASSIS CHAS ...
Page 116: ...INDEX OF TOPICS PRE DELIVERY PRE DE ...
Page 122: ...INDEX OF TOPICS TIME TIME ...
Page 151: ...Seat SADDLE Code Action Duration 1 004003 Saddle Replacement Stalker 50 Time TIME 151 ...