Working with the Gigaset N720 SPK PRO
Operating the measuring handset
The measuring handsets
u
Switch on automatically when they are placed in the charger
u
Are already registered to the measuring base station on delivery
u
Are already in metering mode on delivery.
Display in metering mode
In metering mode, the display shows the current status values of the connection to the
base station. The values are updated at brief intervals. You can change this measuring
interval (
Display in idle status
The display shows the following information in idle status:
The following information is also displayed:
You will find detailed information on evaluating the measurement results in the
section
.
Please note
This section only describes the functions of the handset relevant for measurements.
For information on the standard functions of the Gigaset S810H handset, see the user
guide for the device. See the product page at www.gigaset.com.
Values for determining the connection quality:
RSSI value
value. Base station signal reception
strength with the best reception in
Acceptable value: –20 to –70 dBm.
Units for signal strength
Fr. quality
. Percentage rate of the pack-
ages received without error in the last meas-
uring interval.
Acceptable value: 95–100%
Frequency
. Carrier frequency of the signal received. Value range: 0–9
Slot pair
used (0–11)
Time slot for the reception channel on which the measurement was per-
formed.
Note:
during transition to the connection status, the value 15 is occasion-
ally displayed.
RPN
(Radio Fixed Part Number)
Identifier for the base station to which the handset is connected. The value
is displayed in hexadecimal format.
V
i
RSSI value: -30dBm
Frequency: 1
Slot pair: 04
RPN: 50 hex
Fr. quality: 100 %