27
Taking measurements
¤
Install the measuring base station at this location and take the measurements as for
the first position.
¤
Enter the results in the plan and the measurement log.
¤
Now take this measurement for all planned assembly locations.
Example of a measurement log for measuring the synchronisation overlap
The result of the measurement is that the signal strength is sufficient for synchronisation
everywhere. Base station E only receives base station D with sufficient quality.
Here, a sensible synchronisation hierarchy would be:
Measuring
point
Base station A
Base station B
Base station C
Base station D
Base station E
A
–52 dBm/100% –40 dBm/100% –58 dBm/100% ----
B
–50 dBm/100%
–48 dBm/100% ----
–70 dBm/92%
C
–42 dBm/100% –46 dBm/100%
–50 dBm/100% ----
D
–60 dBm/100% -----
–48 dBm/100%
–64 dBm/100%
E
----
–68 dBm/94%
----
–62 dBm/100%
Sync level 1
Base station C
Sync level 2
Base stations A, B and D
Sync level 3
Base station E
A
B
C
D
E