BIOS Setup
- 89 -
5-3-2-3 ACPI
Parameter
Description
ACPI
ACPI SRAT L3 Cache As
NUMA Domain
Enable/Disable the ACPI SRAT L3 Cache As NUMA Domain function.
Options available: Auto, Enabled, Disabled. Default setting is
Auto
.
ACPI SLIT Distance Control
Determines how the SLIT distances are declared.
Options available: Auto/Manual. Default setting is
Auto
.
ACPI SLIT remote relative
distance
Sets the remote socket distance for 2P systems as near (2.8) or far (3.2).
Options available: Auto, Near, Far. Default setting is
Auto
.