- 27 -
System Hardware Installation
3-4-4 Processor and Memory Module Matrix Table
4 DIMM
Memory Q’ty
for each CPU
CPU1
J0 I0 I1 L0 K0 K1 O1 O0 P0 M1M0 N0
V
1 DIMM
2 DIMM
6 DIMM
8 DIMM
12 DIMM
V
V
V
V
V
V
V
V
V
V
V
V
V
V
V
V
V
V
V
V
V
V
V
V
V
V V
V
V
V
V
V
CPU0
B0 A0 A1 D0 C0 C1 G1 G0 H0 E1 E0 F0
V
V
V
V
V
V
V
V
V
V
V V
V
V
V
V V
V
V
V
V
V
V
V
V
V
V
V
V
V
V
V
V
NOTE!
l
There should be at least one DDR4 DIMM per socket.
l
If only one DIMM is populated in a channel, then populate it in the slot furthest away from CPU of that channel.
l
Channel 0's on each memory controller (A/E/C/G, I/M/K/O) must be populated with same total capacity per channel (if populated).
l
Channel 1's on each memory controller (B/F/D/H, J/N/L/P) must be populated with same total capacity per channel (if populated).
3-4-5 Intel Optane DCPMM DIMM Population Rule
Thermal conditions for DCPMM DIMM support:
• The ambient temperature must be at or below 30°C
• The 3rd Generation Intel® Xeon® Scalable Processors used must have a maximum TDP of 270W
• A maximum of 4 pcs 512G DCPMM may be installed
•
RDIMM must be installed into CPU0 memory first
• You must install one RDIMM into any slot #0 of CPU1 before installing the DCPMM.
(e.g.I0/K0/M0/O0)
• The DCPMM must be installed into the DIMM slot #1 next to the corresponding RDIMM
in slot #0 (e.g. if RDIMM is installed into DIMM slot I0, the DCPMM must be installed into
DIMM slot I1)
CPU0
CPU1
J0/RDIMM Slot
I1/Intel Optane DCPMM Slot
I0/RDIMM Slot
K1/Intel Optane DCPMM Slot
L0/RDIMM Slot
K0/RDIMM Slot
N0/RDIMM Slot
O1/Intel Optane DCPMM Slot
O0/RDIMM Slot
M1/Intel Optane DCPMM Slot
P0/RDIMM Slot
M0/RDIMM Slot
F0/RDIMM Slot
E1/RDIMM Slot
E0/RDIMM Slot
G1/RDIMM Slot
H0/RDIMM Slot
G0/RDIMM Slot
C1/RDIMM Slot
D0/RDIMM Slot
C0/RDIMM Slot
B0/RDIMM Slot
A1/RDIMM Slot
A0/RDIMM Slot
Summary of Contents for G292-280
Page 1: ...G292 280 HPC Server Intel DP 2U 8 x GPU Server User Manual Rev 1 0 ...
Page 28: ... 29 System Hardware Installation For GPU6 GPU7 1 1 2 2 For GPU2 GPU3 1 2 2 1 ...
Page 29: ... 30 System Hardware Installation 3 4 ...
Page 31: ... 32 System Hardware Installation For GPU0 GPU1 1 2 2 1 3 4 ...
Page 33: ... 34 System Hardware Installation 3 4 5 6 6 ...
Page 35: ... 36 System Hardware Installation 5 6 ...
Page 43: ... 44 System Hardware Installation CPU Power Cable 1 x 3 Power Cable ...
Page 44: ... 45 System Hardware Installation SMD Cable System Fan Power Cable ...
Page 47: ... 48 System Hardware Installation SlimLine SAS to SATA 2 Cable NVMe 0 1 Cable NVME 1 NVME 0 ...
Page 48: ... 49 System Hardware Installation NVMe 2 3 Cable NVME 3 NVME 2 Front Panel IO Cable ...
Page 73: ... 74 BIOS Setup 5 2 12 Intel R X710 Ethernet Network Connection ...
Page 78: ... 79 BIOS Setup 5 3 1 Processor Configuration ...