background image

BIOS Setup

- 102 -

5-3-4  NBIO Common Options

Parameter

Description

NBIO Common Options

IOMMU

Enable/Disable the IOMMU function.
Options available: Enabled/Disabled. Default setting is 

Disabled

.

PCIe ARI Support

Enable/Disable Alternative Routng-ID Interpretation.
Options available: Auto, Enabled, Disabled. Default setting is 

Auto

.

PCIe Ten Bit Tag Support

Enable/Disable PCIe ten bit tags for supported devices. (Auto=Disabled)
Options available: Auto, Enabled, Disabled. Default setting is 

Auto

.

SMU Common Options

Press [Enter] for configuration of advanced items.

NBIO RAS Common 
Options

Press [Enter] for configuration of advanced items.

Enable AER Cap

Enable/Disable Advanced Error Reporting Capability.
Options available: Auto, Enabled, Disabled. Default setting is 

Auto

.

Early Link Speed

Configures Early Link Speed.

Options available: Auto, Gen1, Gen2. Default setting is 

Auto

.

Summary of Contents for G262-ZR0

Page 1: ...G262 ZR0 HPC Server 2U DP SXM4 A100 4 GPU Server User Manual Rev 1 0 ...

Page 2: ... and BIOS User Guide detailed information about the installation use of an add on hardware or software component e g BMC firmware rail kit compatible with this product Quick Installation Guide a short guide with visual diagrams that you can reference easily for installation purposes of this product e g motherboard server barebones Please see the support section of the online product page to check ...

Page 3: ...guide NOTE Gives bits and pieces of additional information related to the current topic CAUTION Gives precautionary measures to avoid possible hardware or software problems WARNING Alerts you to any damage that might result from doing or not doing specific actions ...

Page 4: ...here the cord extends from the server WARNING To reduce the risk of personal injury from hot surfaces allow the drives and the internal system components to cool before touching them WARNING This server is equipped with high speed fans Keep away from hazardous moving fan blades during servicing WARNING This equipment is intended to be used in Restrict Access Location The access can only be gained ...

Page 5: ...scharge ESD and ESD protection ESD can damage drives boards and other parts We recommend that you perform all procedures in this chapter only at an ESD workstation If one is not available provide some ESD protection by wearing an antistatic wrist strap attached to chassis ground any unpainted metal surface on the server when handling parts ESD and handling boards Always handle boards carefully The...

Page 6: ...on if battery is replaced incorrectly or with an incorrect type Replace the battery only with the same or equivalent type recommended by the manufacturer Dispose of used bat teries according to the manufacturer s instructions ...

Page 7: ...nd Installing the Fan Duct 25 3 3 Removing the Heat Sink 26 3 4 Installing the CPU 27 3 5 Installing Memory 28 3 5 1 Eight Channel Memory Configuration 28 3 5 2 Installing the Memory 29 3 5 3 DIMM Population Table 29 3 6 Installing the PCI Expansion Card 31 3 7 Replacing the System FAN Module 32 3 8 Installing the Hard Disk Drive 33 3 9 Removing and Installing the Power Supply 34 3 10 Cable Routin...

Page 8: ...uration 75 5 2 20 MAC IPv4 Network Configuration 76 5 2 21 MAC IPv6 Network Configuration 77 5 3 AMD CBS Menu 78 5 3 1 CPU Common Options 79 5 3 2 DF Common Options 84 5 3 3 UMC Common Options 89 5 3 4 NBIO Common Options 102 5 3 5 FCH Common Options 108 5 3 6 NTB Common Options 111 5 3 7 SOC Miscellaneous Control 112 5 4 AMD PBS Menu 113 5 4 1 RAS 114 5 5 Chipset Setup Menu 116 5 5 1 North Bridge...

Page 9: ... points 139 5 10 11 ABL5 test points 139 5 11 Agesa POST Codes 143 5 11 1 Universal Post Code 143 5 11 2 0xA1XX For CZ only memory Postcodes 143 5 11 3 S3 Interface Post Code 146 5 11 4 PMU Post Code 146 5 11 5 0xA5XX assigned for AGESA PSP Module 146 5 11 6 0xA9XX 0xAAXX assigned for AGESA NBIO Module 149 5 11 7 0xACXX assigned for AGESA CCX Module 151 5 11 8 0xADXX assigned for AGESA DF Module 1...

Page 10: ... 10 This page intentionally left blank ...

Page 11: ... dry and first touch a metal object to eliminate static electricity Prior to installing the motherboard please have it on top of an antistatic pad or within an electrostatic shielding container Before unplugging the power supply cable from the motherboard make sure the power supply has been turned off Before turning on the power make sure the power supply voltage has been set according to the loca...

Page 12: ...pported only 8 Channel memory per processor architecture Total up to 4TB 3DS RDIMM LRDIMM modules supported Memory speed Up to 3200 2933 MHz LAN Front side 2 x 1GbE LAN ports 1 x Intel I350 AM2 1 x 10 100 1000 management LAN Video Integrated in Aspeed AST2500 2D Video Graphic Adapter with PCIe bus interface 1920x1200 60Hz 32bpp DDR4 SDRAM Storage 4 x 2 5 Gen4 U 2 NVMe SATA hot swappable HDD SSD ba...

Page 13: ...board NCSI_SW 1 x M 2 slot Onboard M key PCIe Gen4 x4 Supports NGFF 2280 22110 cards 2 x M 2 slos From CMTP072 M key PCIe Gen4 x4 Supports NGFF 2242 2260 2280 22110 cards Internal I O 1 x TPM header 1 x Front panel header Front I O 2 x USB 3 0 1 x mini DP 2 x RJ45 1 x Management LAN 1 x Power button with LED 1 x ID button with LED 1 x Reset button 1 x System status LED 1 x HDD access LED Backplane...

Page 14: ...peed AST2500 management controller AMI MegaRAC SP X Solution web interface Dashboard JAVA Based Serial Over LAN HTML5 KVM Sensor Monitor Voltage RPM Temperature CPU Status etc Sensor Reading History Data FRU Information SEL Log in Linear Storage Circular Storage Policy Hardware Inventory Fan Profile System Firewall Power Consumption Power Control LDAP AD RADIUS Support Backup Restore Configuration...

Page 15: ...n Operating Properties Operating temperature 10 C to 35 C Non operating temperature 40 C to 60 C Operating humidity 8 80 non condensing Non operating humidity 20 95 non condensing System Dimension 2U 448 W x 86 4 H x 760 D mm ...

Page 16: ...ASPEED AST2500 BMC RTL8211E PHY MAC OCP3 0 Mezz TPM Intel i350 xGMI2 18GT s x4 Link 8 Channel DDR4 8 x DIMMs Speed up to 3200MHz 8 Channel DDR4 8 x DIMMs Speed up to 3200MHz 1 x PCIe x16 slot front side 1 x PCIe x16 slot front side SATA III x4 CPU0 AMD ROME Zen2 Core Socket SP3 CPU1 AMD ROME Zen2 Core Socket SP3 2 x PCIe x16 slots rear side 2 x PCIe x16 slots rear side NVIDIA HGX A100 4 GPU Redsto...

Page 17: ... No Description 1 Front Panel LEDs and Buttons 2 PCIe Card Slot 3 PCIe Card Slot 4 Mini DP Port 5 USB 3 0 Port x 2 6 GbE LAN Port x 2 7 10 100 1000 Server Management LAN Port 8 Mezzanine Card Slot Option OCP3 Please Go to Chapter 2 3 Front Panel LED and Buttons for detail description of function LEDs ...

Page 18: ...System Appearance 18 2 2 Rear View PSU1 PSU2 PCIe 2 PCIe 1 PCIe 3 PCIe 4 1 No Description 1 Full Height Half Length PCIe Card Slot x 4 ...

Page 19: ...g the HDD Blink Indicates accessing the HDD Amber On Indicates HDD error Green Amber Blink Indicates HDD rebuilding N A Off Indicates no HDD access or no HDD error 4 ID Button Press the button to activate system identification 5 System Status LED Green On Indicates system is operating normally Amber On Indicates a critical condition may include System fan failure System temperature Blink Indicates...

Page 20: ... Speed LED Yellow On 1 Gbps data rate Green On 100 Mbps data rate N A Off 10 Mbps data rate 2 1GbE Link Activity LED Green On Link between system and network or no access Blink Data transmission or receiving is occurring N A Off No data transmission or receiving is occurring 1 2 1 2 1 2 ...

Page 21: ...ode Green 2Hz Blinking Power supply firmware updating mode Amber On AC cord unplugged or AC power lost with a second power supply in parallel still with AC input power Power supply critical event causing shut down failure OCP OVP fan failure and UVP Amber 1Hz Blinking Power supply warning events where the power supply continues to operate high temp high power high current and slow fan ...

Page 22: ...DD Slot LED on Back Panel Disk LED Removed HDD Slot Green ON 1 OFF BLINK 2 BLINK 2 OFF OFF OFF ON OFF ON 1 OFF OFF ON OFF ON Low Speed 2 Hz 3 3 OFF OFF Green Amber Green ON 1 OFF Green OFF OFF Amber Amber OFF OFF Rebuilding OFF LED1 LED 2 HDD Present No HDD Green ON OFF NOTE 1 Depends on HBA Utility Spec 2 Blink cycle depends on HDD s activity signal 3 If HDD is pulled out during rebuilding the di...

Page 23: ...er you are working inside the system case If possible wear a grounded wrist strap when you are working inside the system case Alternatively discharge any static electricity by touching the bare metal system of the system case or the bare metal body of any other grounded appliance Hold electronic circuit boards by the edges only Do not touch the components on the board unless it is necessary to do ...

Page 24: ...d to AC power Follow these instructions to remove the top rear cover 1 Remove the two screws on the sides of the top cover 2 Unlock the plastic handle and pull the grip handle to open the panel cover 3 Slide the cover to the rear of the system and then remove the cover in the direction indicated by the arrow 4 To reinstall the chassis cover reverse steps 1 3 1 2 3 ...

Page 25: ...ct align the fan duct with the guiding groove Push down the fan duct into chassis until its firmly seats 2 1 1 3 CPU Fan Duct 1 Remove the screws securing the bracket 2 Lift up to remove the bracket 3 Lift up and remove the fan duct 4 To install the fan duct align the fan duct with the guiding groove Push down the fan duct into chassis until its firmly seats 1 1 2 3 3 2 Removing and Installing the...

Page 26: ...eat sink 1 Loosen the captive screws securing the heatsink in place in reverse order 4g3g2g1 2 Lift and remove the heat sink from the system 3 To reinstall the heat sink reverse steps 1 2 while ensuring that you tighten the captive screws in sequential order 1g2g3g4 as seen in the image below 2 4 1 3 ...

Page 27: ...e technician Follow these instructions to install the CPU 1 Loosen the three captive screws in sequential order 1g2g3 securing the CPU cover 2 Flip open the CPU cover 3 Remove the CPU cap with CPU from the CPU frame using the handle on the CPU cap 4 Using the handle on the CPU cap insert the new CPU cap with CPU installed into the CPU frame NOTE Ensure the CPU is installed in the CPU cap in the co...

Page 28: ...o install the memory Make sure that the motherboard supports the memory It is recommended that memory of the same capacity brand speed and chips be used Always turn off the computer and unplug the power cord from the power outlet before installing the memory to prevent hardware damage Memory modules have a foolproof design A memory module can be installed in only one direction If you are unable to...

Page 29: ...install DDR4 DIMMs on this motherboard Follow these instructions to install the Memory 1 Insert the DIMM memory module vertically into the DIMM slot and push it down 2 Close the plastic clip at both edges of the DIMM slots to lock the DIMM module 3 Reverse the installation steps when you want to remove the DIMM module 1 2 2 RDIMM Maximum Frequency Supported Tablel 2R 2 1 DIMMs Populated DIMM 1R 1 ...

Page 30: ...ed Table 4DR 2 1 DIMMs Populated DIMM 2S2R 2S4R 1 1 2 2 1 1 3200 3200 2933 Not Supported 2933 1 2V Frequency MT s NOTE l 1R 1 package rank of SDP DRAMs l 2R 2 package rank of SDP DRAMs l 2DR 2 package rank of DDP DRAMs l 4DR 4 package rank of DDP DRAMs l 2S2R 2S4R 2S8R 2 package rank of 2 4 8 high 3DS DRAMs l When only one DIMM is used it must be populated in memory slot DIMM1 ...

Page 31: ... riser assembly does not include a riser card or any cabling as standard To install a PCI card a riser card must be installed Follow these instructions to PCI Expansion card 1 Remove the screw securing the riser bracket Lift up the riser bracket out of system 2 Loosen and remove the screw securing the slot cover from riser bracket 3 Orient the PCIe card with the riser guide slot and push in the di...

Page 32: ...to the AC power Disconnect all necessary cable connections Failure to observe these warnings could result in personal injury or damage to the equipment Follow these instructions to replace the system fan module For all system fan modules 1 Grasp the finger slots of the fan module and pull up to remove the fan module 2 Reverse the previous steps to install the replacement fan module 2 2 1 1 ...

Page 33: ... is connected to the HDD connector on the backplane Follow these instructions to install a 2 5 hard disk drive 1 Press the release button 2 Extend the locking lever 3 Pull the locking lever in the direction indicated to remove the 2 5 HDD tray 4 Orient the hard disk drive so the opening on the rear of the hard disk drive is aligned to the positioning stud on the HDD tray 5 Slide the hard disk driv...

Page 34: ...he power supply in the direction indicated 3 Pull out the power supply using the handle 4 Insert the replacement power supply firmly into the chassis Connect the AC power cord to the replacement power supply 1 3 2 4 CAUTION In order to reduce the risk of injury from electric shock disconnect AC power from the power supply before removing the power supply from the system Please see Section 2 2 Rear...

Page 35: ... 35 System Hardware Installation 3 10 Cable Routing Front Switch Cable Front LED Cable GPU Power Cable ...

Page 36: ...System Hardware Installation 36 HDD Back Plane Board Power Cable HDD Back Plane Board Signal Cable ...

Page 37: ... 37 System Hardware Installation HDD Back Panel Board NVMe Signal Cable ...

Page 38: ...System Hardware Installation 38 PCIe Signal Cable ...

Page 39: ... 39 System Hardware Installation System Power Cable Power Supply Signal Cable ...

Page 40: ...System Hardware Installation 40 On Board SATA Cable ...

Page 41: ...B 3 0 Port x 2 8 Mini DP Port 9 Serial Port Cable Connector 10 M 2 Connector PCIe x4 Supports NGFF 22110 11 IPMB Connector 12 Proprietary PCIe Slot L Gen 4 x8 slot GENZ_L 13 SlimLine SAS Connector SL4_SATA0 PCIe SATA 14 Power PCIe SATA Connector 15 Power PCIe SATA Connector 16 Power PCIe SATA Connector 17 SGPIO Connector B 18 SGPIO Connector A 19 Proprietary PCIe Slot R Gen 4 x16 slot GENZ_R 20 Pr...

Page 42: ...1 21 21 3 ON BIOS recovery mode Normal Default BIOS Defined Clear supervisor password OFF HOST_SMBUS_SEL NA NA BIOS_PWD BIOS_RCVR Normal Default J1 1 2 3 4 Clear CMOS CLR_CMOS Enable Default 1 2 3 NCSI Switch 21 Onboard LAN OCP 3 0 Mezzanine OFF ON ...

Page 43: ... with caution Inadequate BIOS flashing may result in system malfunction It is recommended that you not alter the default settings unless you need to to prevent system instability or other unexpected results Inadequately altering the settings may result in system s failure to boot If this occurs try to clear the CMOS values and reset the board to default values Refer to the Exit section in this cha...

Page 44: ...f the North Bridge Server Management Server additional features enabled disabled setup menus Security Change set or disable supervisor and user password Configuration supervisor password allows you to restrict access to the system and BIOS Setup A supervisor password allows you to make changes in BIOS Setup A user password only allows you to view the BIOS settings but not to make changes Boot This...

Page 45: ... displayed on the bottom line of the Main Menu Submenu Help While in a submenu press F1 to display a help screen General Help of function keys available for the menu Press Esc to exit the help screen Help for each item is in the Item Help block on the right side of the submenu When the system is not stable as usual select the Restore Defaults item to set your system to its defaults The BIOS Setup ...

Page 46: ...e of the installed memory Memory Frequency Note3 Displays the frequency information of the installed memory VR Information Version Displays VR version information AGESA PI Version PI Version Displays AGESA PI version information Onboard LAN Information LAN1 MAC Address Note1 Displays LAN MAC address information LAN2 MAC Address Note2 Displays LAN MAC address information System Date Sets the date f...

Page 47: ... Menu The Advanced Menu displays submenu options for configuring the function of various hardware components Select a submenu item then press Enter to access the related submenu screen When Boot Mode Select is set to UEFI Default ...

Page 48: ...etup 48 When Boot Mode Select is set to Legacy in the Boot Boot Mode Select section Parameter Description ErP Mode Enable Disable ErP Lot 9 suuport Options available Enable Disable Default setting is Disable ...

Page 49: ...ble BIOS support for security device OS will not show security device TCG EFI protocol and INT1A interface will not be available Options available Enable Disable Default setting is Enable SPI TPM Support Select Enable to activate TPM support feature Options available Enabled Disabled Default setting is Disabled ...

Page 50: ...BIOS Setup 50 5 2 2 PSP Firmware Versions The PSP Firmware Versions page displays the basic PSP firmware version information Items on this window are non configurable ...

Page 51: ...OnBrd Ext VGA Select Note Selects between onboard or external VGA support Options available Auto Onboard External Default setting is Onboard Note This configurable option will be displayed when Boot Mode Select is set to Legacy in the Boot Boot Mode Select section ...

Page 52: ... 2 4 AST2500 Super IO Configuration Parameter Description AST2500 Super IO Configuration Super IO Chip Displays the super IO chip information Serial Port 1 Configuration Press Enter for configuration of advanced items ...

Page 53: ... 43 BIOS Setup 5 2 4 1 Serial Port 1 Configuration ...

Page 54: ...Devices Settings Note2 Displays the Serial Port 1 2 device settings Change Settings Note2 Select an optimal settings for Super IO Device Options available for Serial Port 1 Auto IO 3F8h IRQ 4 IO 3F8h IRQ 3 4 5 6 7 9 10 11 12 IO 2F8h IRQ 3 4 5 6 7 9 10 11 12 IO 3E8h IRQ 3 4 5 6 7 9 10 11 12 IO 2E8h IRQ 3 4 5 6 7 9 10 11 12 Default setting is Auto Options available for Serial Port 2 Auto IO 2F8h IRQ...

Page 55: ...tion Wake System from S5 Note1 Enable Disable system wake on alarm event Options available Disabled Fixed Time When Fixed Time enabled system will wake on the hr min sec specified Default setting is Disabled Note1 Advanced items prompt when this item is defined ...

Page 56: ...r LAN Console Redirection Settings Press Enter to configure advanced items Please note that this item is configurable when COM1 Serial Over LAN COM2 Console Redirection is set to Enabled Terminal Type Selects a terminal type to be used for console redirection Options available VT100 VT100 ANSI VT UTF8 Default setting is ANSI Bits per second Selects the transfer rate for console redirection Options...

Page 57: ... 2 Default setting is 1 Flow Control Flow control can prevent data loss from buffer overflow When sending data if the receiving buffers are full a stop signal can be sent to stop the data flow Once the buffers are empty a start signal can be sent to re start the flow Hardware flow control uses two wires to send start stop signals Options available None Hardware RTS CTS Default setting is None VT U...

Page 58: ...MS Console Redirection Note EMS console redirection allows the user to configure Console Redirection Settings to support Out of Band Serial Port management Options available Enabled Disabled Default setting is Disabled Serial Port for Out of Band EMS Console Redirection Settings Press Enter to configure advanced items Please note that this item is configurable when Serial Port for Out of Band Mana...

Page 59: ...ta loss from buffer overflow When sending data if the receiving buffers are full a stop signal can be sent to stop the data flow Once the buffers are empty a start signal can be sent to re start the flow Hardware flow control uses two wires to send start stop signals Options available None Hardware RTS CTS Software Xon Xoff Default setting is None ...

Page 60: ...e the CPU Virtualization Options available Enabled Disabled Default setting is Enabled SMEE Controls the Secure Memory Encryption Enable SMEE function Options available Enabled Disabled Default setting is Enabled CPU 0 1 Information Press Enter to view more information related to CPU ...

Page 61: ... 43 BIOS Setup 5 2 8 AMI Graphic Output Protocol Policy Parameter Description ASPEED Graphics PCI Adapter ASPEED Graphics Driver Output Select Press Enter to select output interface ...

Page 62: ...BIOS Setup 62 5 2 9 PCI Subsystem Settings ...

Page 63: ...nabled Disabled Default setting is Enabled OCP3 0 Max Link Speed Configure OCP max link speed Options available Auto Maximum Gen1 Gen2 Gen3 Gen4 Default setting is Auto Onboard LAN Controller Note2 Enable Disable the onboard LAN devices Options available Enabled Disabled Default setting is Enabled Onboard LAN I O ROM Note2 Enable Disable the onboard LAN devices and initializes device expansion ROM...

Page 64: ...ff Enable Disable the XHCI USB 3 0 Hand off support Options available Enabled Disabled Default setting is Enabled USB Mass Storage Driver Support Note Enable Disable the USB Mass Storage Driver Support Options available Enabled Disabled Default setting is Enabled Port 60 64 Emulation Enables the I O port 60h 64h emulation support This should be enabled for the complete USB Keyboard Legacy support ...

Page 65: ...for a Root port it is 100 ms for a Hub port the delay is taken from Hub descriptor Options available Auto Manual Default setting is Auto Mass Storage Devices AMI Virtual CDROM0 1 00 AMI HDisk0 1 00 Generic Flash Disk 8 07 ADATA USB Flash Drive 1100 Mass storage device emulation type AUTO enumerates devices according to their media format Optical drives are emulated as CDROM drives with no media wi...

Page 66: ...setting is Disabled Ipv6 PXE Support Note Enable Disable the Ipv6 PXE feature Options available Enabled Disabled Default setting is Enabled Ipv6 HTTP Support Note Enable Disable the Ipv6 HTTP feature Options available Enabled Disabled Default setting is Disabled IPSEC Certificate Note Enable Disable the IPSEC Certificate feature Options available Enabled Disabled Default setting is Enabled PXE boo...

Page 67: ... 43 BIOS Setup 5 2 12 NVMe Configuration Parameter Description NVMe Configuration Displays the NVMe devices connected to the system ...

Page 68: ...BIOS Setup 68 5 2 13 SATA Configuration Parameter Description SATA Configuration Displays the installed HDD devices information System will automatically detect HDD type ...

Page 69: ... 43 BIOS Setup 5 2 14 UEFI POST LOGO Configuration Parameter Description UEFI Configuration Select output device type ...

Page 70: ...iguration of advanced items Enroll Cert Press Enter to enroll a certificate Enroll Cert Using File Cert GUID Input digit character in 1111111 2222 3333 4444 1234567890ab format Commit Changes and Exit Discard Changes and Exit Delete Cert Client Cert Configuration Press Enter for configuration of advanced items ...

Page 71: ... 43 BIOS Setup 5 2 16 AMD Mem Configuration Status Parameter Description CPU0 1 Press Enter to view the memory configuration status related to CPU 0 ...

Page 72: ...nitiator Name Press Enter and name iSCSI Initiator Only IQN format is accecpted Range from 4 to 223 Add an Attempt Press Enter to configure advanced items Delete Attempts Press Enter to configure advanced items Change Attempt Order Press Enter to configure advanced items ...

Page 73: ... 43 BIOS Setup 5 2 18 Intel R Ethernet Controller I350 ...

Page 74: ... Press the numeric keys to adjust desired values UEFI Driver Displays the technical specifications for the Network Interface Controller Adapter PBA Displays the technical specifications for the Network Interface Controller Device Name Displays the technical specifications for the Network Interface Controller Chip Type Displays the technical specifications for the Network Interface Controller PCI D...

Page 75: ...ng VLAN Press the keys to increase or decrease the desired values The valid range is from 0 to 4094 Priority Sets 802 1Q Priority for a new VLAN or an existing VLAN Press the keys to increase or decrease the desired values The valid range is from 0 to 7 Add VLAN Press Enter to create a new VLAN or update an existing VLAN Configured VLAN List Remove VLAN Press Enter to remove an existing VLAN ...

Page 76: ...Note Options available Enabled Disabled Default setting is Enabled Local IP Address Note Press Enter to configure local IP address Local NetMask Note Press Enter to configure local NetMask Local Gateway Note Press Enter to configure local Gateway Local DNS Servers Note Press Enter to configure local DNS servers Save Changes and Exit Press Enter to save all configurations Note This item appears whe...

Page 77: ... for the device The string is colon separated e g ff dd 88 66 cc 1 2 3 DAD Transmit Count The number of consective Neighbor solicitation messages sent while performing Duplicate Address Detection on a tentative address A value of zero indicates that Duplicate Address Detection is not performed Policy Options available automatic manual Default setting is automatic Save Changes and Exit Press Enter ...

Page 78: ... 78 5 3 AMD CBS Menu AMD CBS menu displays submenu options for configuring the CPU related information that the BIOS automatically sets Select a submenu item then press Enter to access the related submenu screen ...

Page 79: ...EH cloak individual banks and mask deferred error interrupts from each bank Options available Auto Enabled Disabled Default setting is Auto Core Performance Boost Enable Disable the Core Performance Boost function Options available Auto Disabled Default setting is Auto Global C State Control Controls the IO based C state generation and DF C states Options available Auto Enabled Disabled Default se...

Page 80: ...le Auto Enabled Disabled Default setting is Auto MCA error thresh enable Enable MCA error thresholding Options available Auto False True Default setting is Auto SMU and PSP Debug Mode When this option is enabled specific uncorrected errors detected by the PSP FW or SMU FW will hand and not reset the system Options available Auto Enabled Disabled Default setting is Auto Xtrig7 Workaround Options av...

Page 81: ...e Pstates When accepted you can disable or customize core pstates CCD Core Thread Enablement Allows you to accept or decline enabling CCDs processor cores and threads When accepted you can control the number of CCDs to be used the number of cores to be used and whether to enable or disable Simultaneous Multithreading Technology SMT support ...

Page 82: ...tcher settings L1 Stream HW Prefetcher Enable Disable L1 Stream HW Prefetcher Options available Auto Enable Disabled Default setting is Enable L2 Stream HW Prefetcher Enable Disable L2 Stream HW Prefetcher Options available Auto Enable Disabled Default setting is Enable ...

Page 83: ... 43 BIOS Setup 5 3 1 3 Core Watchdog Parameter Description Core Watchdog Core Watchdog Timer Enable Enable Disable CPU Watchdog Timer Options available Auto Enabled Disabled Default setting is Auto ...

Page 84: ...Disable DF Sync Flood propagation Options available Auto Sync flood disabled Sync flood enabled Default setting is Auto Frezze DF module queues on error Options available Auto Enabled Disabled Default setting is Auto CC6 memory region encryption Controls whether or not the CC6 save restor memory is encrypted Options available Auto Enabled Disabled Default setting is Auto System probe filter Enable...

Page 85: ...he Poison scrubber control feature Options available Auto Enabled Disabled Default setting is Auto Redirect scrubber control Enable Disable the Redirect scrubber control feature Options available Auto Enabled Disabled Default setting is Auto Redirect scrubber limit Sets the redirect scrubber limit Options available Auto 2 4 8 Infinite Default setting is Auto Periodic Directory Rinse Control Period...

Page 86: ... remap Enable Disable to remap DRAM out of the space just below the 1TB boundary The ability to remap depends on DRAM configuration NPS and interleaving selection and may not always be possible Options available Auto Do not remap Attempt to remap Default setting is Auto DRAM map inversion Enable Disable the DRAM map inversion function Options available Auto Enabled Disabled Default setting is Auto...

Page 87: ...Options available Auto Enabled Disabled Default setting is Auto ACPI SLIT Distance Control Determines how the SLIT distances are declared Options available Auto Manual Default setting is Auto ACPI SLIT remote relative distance Sets the remote socket distance for 2P systems as near 2 8 or far 3 2 Options available Auto Near Far Default setting is Auto ...

Page 88: ...f bounds Control Options available Auto Manual Default setting is Auto 4 link xGMI max speed Specifies the max speed of 4 link xGMI Options available Auto 10 667Gbps 13Gbps 16Gbps 18Gbps Default setting is 10 667Gbps 3 link xGMI max speed Specifies the max speed of 3 link xGMI Options available Auto 10 667Gbps 13Gbps 16Gbps 18Gbps Default setting is 10 667Gbps xGMI TXEQ Mode Configures xGMI TXEQ R...

Page 89: ... Common Options DDR4 Common Options Press Enter for configuration of advanced items DRAM Memory Mapping Press Enter for configuration of advanced items NVDIMM Press Enter for configuration of advanced items Memory MBIST Press Enter for configuration of advanced items ...

Page 90: ...To enable 2 DIMMs per Channel at 3200MHz function select Accept at warning message change Overclock from Auto to Enabled and then set memory speed to 3200MHz DRAM Controller Configuration Press Enter to configure DRAM Controller Configuration CAD Bus Configuration Press Enter to configure CAD Bus Configuration Data Bus Configuration Press Enter to configure Data Bus Configuration Common RAS Press ...

Page 91: ...DRAM Power OptionsMa Power Down Enable Enable Disable DDR power down mode Options available Auto Enabled Disabled Default setting is Auto Cmd2T Selects the Cmd2T mode on ADDR CMD Options available Auto 1T 2T Default setting is Auto Gear Down Mode Enable Disable the Gear Down Mode function Options available Auto Enabled Disabled Default setting is Auto ...

Page 92: ...guration CAD Bus Timing User Controls Setup time on CAD bus signals to Auto or Manual Options available Auto Manual Default setting is Auto CAD Bus Drive Strength User Controls Drive Strength on CAD bus signals to Auto or Manual Options available Auto Manual Default setting is Auto ...

Page 93: ...3 1 3 Data Bus Configuration Parameter Description Data Bus Configuration Data Bus Configuration User Controls Specifies the mode for drive strength to Auto or Manual Options available Auto Manual Default setting is Auto ...

Page 94: ...tion Options available Auto Enabled Disabled Default setting is Auto Max Parity Error Replay Configures the Max Parity Error Replay 0 0x3f Default setting is 8 Please note that this item is configurable when DRAM Address Command Parity Retry is set to Enabled Write CRC Enable Enable Disable the Write CRC function Options available Auto Enabled Disabled Default setting is Auto DRAM Write CRC Enable...

Page 95: ...tems DRAM ECC Symbol Size Configures the DRAM ECC Symbol Size Options available Auto x4 x8 x16 Default setting is Auto DRAM ECC Enable Enable Disable DRAM ECC When set to Auto it will set ECC to enable Options available Auto Enabled Disabled Default setting is Auto DRAM UECC Retry Enable Disable DRAM UECC Retry Options available Auto Enabled Disabled Default setting is Auto ...

Page 96: ...rameter Description Security TSME Enable Disable Transparent SME Options available Auto Enabled Disabled Default setting is Auto Data Scramble Enable Disable Data Scrambling Options available Auto Enabled Disabled Default setting is Auto ...

Page 97: ... No help string Options available Auto Enabled Disabled Default setting is Auto BankGroupSwapAlt Configures the BankGroupSwapAlt Options available Auto Enabled Disabled Default setting is Auto Address Hash Bank Enable Disable bank address hashing Options available Auto Enabled Disabled Default setting is Auto Address Hash CS Enable Disable CS address hashing Options available Auto Enabled Disabled...

Page 98: ...BIOS Setup 98 5 3 3 3 NVDIMM Parameter Description NVDIMM Disable NVDIMM N feature for memory margin tool Options available No Yes Default setting is No ...

Page 99: ...easures Voltage vs Timing Options available Auto Both Interface Mode Data Eye Mode Default setting is Auto MBIST Aggressors Note Enable Disable MBIST Aggressor test Options available Auto Enabled Disabled Default setting is Auto MBIST Per Bit Slave Die Reporting Note Enable Disable to report 2D data eye results in ABL log for each DQ Chipselect and Channel Options available Auto Enabled Disabled D...

Page 100: ...ol function Options available Enabled Disabled Default setting is Disabled Aggressor Static Lane Select Upper 32 bits This item is configurable when Aggressor Static Lane Control is set to Enabled Aggressor Static Lane Select Lower 32 bits This item is configurable when Aggressor Static Lane Control is set to Enabled Aggressor Static Lane Select ECC This item is configurable when Aggressor Static ...

Page 101: ...Voltage Sweep 1D Timing Sweep 2D Full Data Eye Worst Case Margin Only Default setting is Worst Case Margin Only Worst Case Margin Granularity Configures Worst Case Margin Granularity Options available Per Chip Select Per Nibble Default setting is Worst Case Margin Only Read Voltage Sweep Step Size Configures the step size for read Data Eye voltage sweep Options available 1 2 4 Default setting is 2...

Page 102: ... Ten Bit Tag Support Enable Disable PCIe ten bit tags for supported devices Auto Disabled Options available Auto Enabled Disabled Default setting is Auto SMU Common Options Press Enter for configuration of advanced items NBIO RAS Common Options Press Enter for configuration of advanced items Enable AER Cap Enable Disable Advanced Error Reporting Capability Options available Auto Enabled Disabled D...

Page 103: ...mode Controls the Presence Detect Select mode Options available Auto OR AND Default setting is Auto Preferred IO Device Configures Preferred IO Device Options available Auto Manual Default setting is Auto Loopback Mode Enabled Disabled PCIe Loopback mode Options available Auto Enabled Disabled Default setting is Auto CV test Set this to Enabled to support running PCIECV tool Auto preserve hardware...

Page 104: ... or set customized TDP TDP is used to define the RC thermal model only Options available Auto Manual Default setting is Auto CLD0_VDDP Control Options available Auto Manual Default setting is Auto EfficiencyModeEn Options available Auto Enabled Default setting is Auto Package Power Limit Control Selects use the fused PPT or set customized PPT PPT will be used as the ASIC power limit Options availa...

Page 105: ...ature Options available Auto Enabled Disabled Default setting is Auto HSMP Support Select HSMP support enable or disable Options available Auto Enabled Disabled Default setting is Auto Diagnostic Mode Select Diagnostic Mode enable or disable Options available Auto Enabled Disabled Default setting is Auto BoostFmaxEn Options available Auto Enabled Default setting is Auto ...

Page 106: ...y on the associated IOHC egress port A bit of 0 indicates LOW serverity NBIO SyncFlood Generation The value may be used to mask SyncFlood caused by NBIO RAS options Options available Auto Enabled Disabled Default setting is Auto NBIO SyncFlood Reporting The value may be used to enanle SyncFlood reporting to APML Options available Enabled Disabled Default setting is Disabled Egress Poison Mask High...

Page 107: ...Default setting is Disabled SLINK Read Response Error Handling Options available Enabled Trigger MCOMMIT Error Log Errors in MCA Default setting is Log Errors in MCA Log Poison Data from SLINK Enable Disable the Log Poison Data from SLINK feature Options available Enabled Disabled Default setting is Disabled PCIe Aer Reporting Mechanism Selects the method of reporting AER errors from PCI Express O...

Page 108: ...etup 108 5 3 5 FCH Common Options Parameter Description FCH Common Options AC Power Loss Options Press Enter for configuration of advanced items FCH RAS Options Press Enter for configuration of advanced items ...

Page 109: ... Setup 5 3 5 1 AC Power Loss Options Parameter Description AC Power Loss Options AC Loss Control Selects the AC Loss Control Method Options available Power Off Power On Last State Default setting is Last State ...

Page 110: ...ALink RAS Support Enable Disable the ALink RAS Support Options available Auto Enabled Disabled Default setting is Auto Reset after sync flood Enables AB to forward downstream sync flood message to system controller Options available Auto Enabled Disabled Default setting is Auto ...

Page 111: ... 43 BIOS Setup 5 3 6 NTB Common Options Parameter Description NTB Common Options NTB Enable Options available Auto Enabled Default setting is Auto ...

Page 112: ...nable Disable the ConsoleOut function for ABL Options available Auto Enabled Disabled Default setting is Auto ABL PMU message Control Note To Control the total number of PMU debug messages Options available Auto Enabled Disabled Default setting is Auto Note This item appears when ABL Console Out Control is set to Enabled ...

Page 113: ...he function of AMD PBS Select a submenu item then press Enter to access the related submenu screen Parameter Description RAS Press Enter for configuration of advanced items SPI Locking Enable Disable SPI Locking for protect ROM part Options available Enabled Disabled Default setting is Disabled ...

Page 114: ...Period GHES Notify Type Selects the Notification type for deferred corrected errors Options available Polled SCI Default setting is Polled GHES UnCorr Notify Type Selects the Notification type for uncorrected errors Options available Polled NMI Default setting is NMI PCIe GHES Notify Type Selects the Notification type for PCIe corrected errors Options available Polled SCI Default setting is Polled...

Page 115: ... the PCIe AER Uncorrected Error Serverity register of PCIe device CCIX GHES Deferred ERR Notify Type Selects the Notification type for CCIX deffered error Options available Polled SCI Default setting is Polled CCIX GHES Corrected Err Notify Type Selects the Notification type for CCIX corrected error Options available Polled SCI Default setting is Polled DDR4 DRAM Hard Post Package Repair This feat...

Page 116: ...e Link Training Type Configures the PCIe Link training in 1 or 2 steps Options available 1 Step 2Step Default setting is 1 Step PCIe Compliance Mode Options available On Off Default setting is Off Program All VR Enable Disable program all VR on MB Options available Enabled Disabled Default setting is Enabled North Bridge Press Enter for configuration of advanced items Fabric Resource Press Enter f...

Page 117: ... Setup 5 5 1 North Bridge Parameter Description North Bridge Configuration Memory Information Total Memory Displays the total memory information CPU0 Information Press Enter to view information related to CPU 0 ...

Page 118: ...BIOS Setup 118 5 5 2 Fabric Resource Parameter Description Fabric Resource Socket 0 1 NBIO_ PCIe Bus Number Change Socket 0 1 NBIO_ PCIe Bus Number ...

Page 119: ...set Power Down Default setting is Do Nothing Please note that this item is configurable when FRB 2 Timer is set to Enabled OS Watchdog Timer Enable Disable OS Watchdog Timer function Options available Enabled Disabled Default setting is Disabled OS Wtd Timer Timeout Configures OS Watchdog Timer Options available 5 minutes 10 minutes 15 minutes 20 minutes Default setting is 10 minutes Please note t...

Page 120: ...vent Log Press Enter to configure advanced items View FRU Information Press Enter to view the FRU information BMC network configuration Press Enter to configure advanced items IPv6 BMC Network Configuration Press Enter to configure advanced items ...

Page 121: ...e SEL Choose options for erasing SEL Options available No Yes On next reset Yes On every reset Default setting is No When SEL is Full Choose options for reactions to a full SEL Options available Do Nothing Erase Immediately Default setting is Do Nothing Custom EFI Logging Options Log EFI Status Codes Enable Disable the logging of EFI Status Codes if not already converted to legacy Options availabl...

Page 122: ...U Information The FRU page is a simple display page for basic system ID information as well as System product information Items on this window are non configurable Note The model name will vary depends on the product you purchased ...

Page 123: ...ilable Unspecified Static DynamicBmcDhcp Default setting is DynamicBmcDhcp Station IP address Displays IP Address information Subnet mask Displays Subnet Mask information Please note that the IP address must be in three digitals for example 192 168 000 001 Router IP address Displays the Router IP Address information Station MAC address Displays the MAC Address information Real time get BMC network...

Page 124: ...work during BIOS phase Options available Unspecified Disable Enable Default setting is Enable IPv6 BMC Lan IP Address Source Selects to configure LAN channel parameters statically or dynamically by BIOS or BMC Options available Unspecified Static Dynamic Obtained by BMC running DHCP Default setting is Enable Dynamic Obtained by BMC running DHCP IPv6 BMC Lan IP Address Prefix Length Check if the IP...

Page 125: ...ll settings in the Setup Utility User Password Entering this password will restrict a user s access to the Setup menus To enable or disable this field a Administrator Password must first be set A user can only access and modify the System Time System Date and Set User Password fields Parameter Description Administrator Password Press Enter to configure the administrator password User Password Pres...

Page 126: ...Secure Boot requires all the applications that are running during the booting process to be pre signed with valid digital certificates This way the system knows all files being loaded before Windows loads to the login screen have not been tampered with When set to Standard it will automatically load the Secure Boot keys form the BIOS databases When set to Custom you can customize the Secure Boot s...

Page 127: ... Key Exchange Keys KEK Displays the current status of the Key Exchange Key Database KEK Press Enter to configure a new KEK or load additional KEK from storage devices Options available Set New Append Authorized Signatures DB Displays the current status of the Authorized Signature Database Press Enter to configure a new DB or load additional DB from storage devices Options available Set New Append ...

Page 128: ...ber of seconds to wait for setup activation key 65535 0xFFFF means indefinite waiting Press the numeric keys to input the desired values Bootup NumLock State Enable Disable the Bootup NumLock function Options available On Off Default setting is Off Quiet Boot Enable Disable showing the logo during POST Options available Enabled Disabled Default setting is Enabled Boot mode select Selects the boot ...

Page 129: ...ure the boot priority By default the server searches for boot devices in the following sequence 1 Hard drive 2 CD COM DVD drive 3 USB device 4 Network 5 UEFI UEFI Network Drive BBS Priorities Press Enter to configure the boot priority UEFI Application Boot Priorities Press Enter to configure the boot priority ...

Page 130: ...rities The UEFI network drive BBS priorities submenu allows you to specify the boot device priority from the available UEFI network drives during system boot up BIOS setup will display an error message if the legacy drive s specified is not bootable ...

Page 131: ...orities The UEFI application boot priorities submenu allows you to specify the boot device priority from the available UEFI applications during system boot up BIOS setup will display an error message if the legacy drive s specified is not bootable ...

Page 132: ...ne so far to any of the setup options Options available Yes No Default Options Restore Defaults Loads the default settings for all BIOS setup parameters Setup Defaults are quite demanding in terms of resources consumption If you are using low speed memory chips or other kinds of low performance components and you choose to load these settings the system might not function properly Options availabl...

Page 133: ...ace 0xE00D ProcMemPhyFenceTraining 0xE00E ProcMemSynchronizeDcts 0xE00F ProcMemSystemMemoryMapping 0xE010 ProcMemMtrrConfiguration 0xE011 ProcMemDramTraining 0xE012 ProcMemBeforeAnyTraining Public interface 0xE013 5 10 3 PMU Test Points ABL Mem PMU Before PMU Firmware load 0xE014 ABL Mem PMU After PMU Firmware load 0xE015 ABL Mem PMU Populate SRAM Timing 0xE016 ABL Mem PMU Populate SRAM Config 0xE...

Page 134: ...ABL Mem Read Test pattern 0xE036 ABL Mem Compare Test pattern 0xE037 ABL Mem Online Spare init 0xE038 ABL Mem Chip select Interleave Init 0xE039 ABL Mem Node Interleave Init 0xE03A ABL Mem Channel Interleave Init 0xE03B ABL Mem ECC initialization 0xE03C ABL Mem Platform Specific Init 0xE03D ABL Mem Before callout for AgesaReadSpd 0xE03E ABL Mem After callout for AgesaReadSpd 0xE03F ABL Mem Before ...

Page 135: ... init 0xE057 Exit point CPU APOB EDC info init 0xE058 5 10 6 Topology test points ProcTopologyEntry 0xE071 ProcTopologyDone 0xE07C 5 10 7 Extended memory test point ProcMemSendMRS2 0xE080 Sedding MRS3 0xE081 Sending MRS1 0xE082 Sending MRS0 0xE083 Continuous Pattern Read 0xE084 Continuous Pattern Write 0xE085 Mem 2d RdDqs Training begin 0xE086 Mem Before optional callout to platform BIOS to change...

Page 136: ...ode 0xE09F TP0xA0 0xE0A0 GNB internal debug code 0xE0A1 GNB internal debug code 0xE0A2 GNB internal debug code 0xE0A3 GNB internal debug code 0xE0A4 GNB internal debug code 0xE0A5 GNB internal debug code 0xE0A6 GNB internal debug code 0xE0A7 GNB internal debug code 0xE0A8 GNB internal debug code 0xE0A9 GNB internal debug code 0xE0AA GNB internal debug code 0xE0AB GNB internal debug code 0xE0AC GNB...

Page 137: ... Initialization Stage 4 Warning 0xF4C0 ABL 3 GMI xGMI Initialization Stage 4 Error 0xE5C0 ABL 3 GMI xGMI Initialization Stage 5 0xB5C0 ABL 3 GMI xGMI Initialization Stage 5 Warning 0xF5C0 ABL 3 GMI xGMI Initialization Stage 5 Error 0xE6C0 ABL 3 GMI xGMI Initialization Stage 6 0xB6C0 ABL 3 GMI xGMI Initialization Stage 6 Warning 0xF6C0 ABL 3 GMI xGMI Initialization Stage 6 Error 0xE7C0 ABL 3 GMI xG...

Page 138: ...n AP 0xE0E0 Before IDS calls out to get IDS data 0xE0E1 After IDS calls out to get IDS data 0xE0E2 Before the heap manager calls out to allocate a buffer 0xE0E3 After the heap manager calls out to allocate a buffer 0xE0E4 Before the heap manager calls out to deallocate a buffer 0xE0E5 After the heap manager calls out to deallocate a buffer 0xE0E6 Before the heap manager calls out to locate a buffe...

Page 139: ... Initialization 0xE103 End of phase 1b memory code 0xE104 ABL 1b memory initialization 0xE105 ABL 6 Global memroy error detected 0xE106 ABL 1b Debug Synchronization Function 0xE107 ABL 4b Debug Synchronization Function 0xE108 AblbBegin 0xE109 Ab4bBegin 0xE10A BSP encountered HMAC fail on APOB Header 0xE10B ABL Eroor General ASSERT 0xE2A0 Unknown Error 0xE2A1 ABL Error Log Inig Error 0xE2A2 ABL Err...

Page 140: ...r DDR Recovery error 0xE2BE ABL Error for RRW Test error 0xE2BF ABL Error for On Die Thermal error 0xE2C1 ABL Error for Heap Allocation For Dct Struct Amd Ch Def structure error 0xE2C2 ABL Error for Heap Allocation for PMU SRAM Msg block error 0xE2C3 ABL Error for Heap Phy PLL lock Flure error 0xE2C4 ABL Error for Pmu Training error 0xE2C5 ABL Error for Failure to Load or Verify PMU FW error 0xE2C...

Page 141: ... Error 0xE2EB ABL Error MBIST Heap Allocation Error 0xE2EC ABL Error MBIST Results Error 0xE2EE ABL Error NO Dimm Smcus Info Error 0xE2EE ABL Error Por Max Freq Table Error 0xE2EF ABL Error Unsupproted DIMM Config Error 0xE2F0 ABL Error No Ps Table Error 0xE2F1 ABL Error Cad Bus Timing Not Found Error 0xE2F2 ABL Error Data Bus Timing Not Found Error 0xE2F3 ABL Error LrDIMM IBT Not Found Error 0xE2...

Page 142: ...E30A ABL Error message slave sync function execution Error 0xE30B ABL Error slave offline Error 0xE30C ABL Error Sync Master Error 0xE30D ABL Error Slave Informs Master Info Message Error 0xE30E ABL Error General Assert Error 0xE30F ABL Error No Dimms On Any Channel in sysem 0xE310 ABL Alert PMU Major Message captured 0xE311 ABL Alert PMU REsults Rx Timing captured 0xE312 ABL Alert PMU REsults Tx ...

Page 143: ...A107 TpProcMemSpdTiming 0xA108 TpProcMemDramMapping 0xA109 TpProcMemPlatformSpecificConfig 0xA10A TPProcMemPhyCompensation 0xA10B TpProcMemStartDcts 0xA10C Public interface 0xA10D TpProcMemPhyFenceTraining 0xA10E TpProcMemSynchronizeDcts 0xA10F TpProcMemSystemMemoryMapping 0xA110 TpProcMemMtrrConfiguration 0xA111 TpProcMemDramTraining 0xA112 Public interface 0xA113 TpProcMemWriteLevelizationTraini...

Page 144: ... Start sweep 0xA133 Set delay 0xA134 Write test pattern 0xA135 Read Test pattern 0xA136 Compare Test pattern 0xA137 Online Spare init 0xA138 Bank Interleave Init 0xA139 Node Interleave Init 0xA13A Channel Interleave Init 0xA13B ECC initialization 0xA13C Platform Specific Init 0xA13D Before callout for AgesaReadSpd 0xA13E After callout for AgesaReadSpd 0xA13F Before optional callout AgesaHookBefore...

Page 145: ...xA187 Mem After optional callout to platform BIOS to change External Vref during 2d Training 0xA188 Configure DCT For General use begin 0xA189 Configure DCT For training begin 0xA18A Configure DCT For Non Explicit 0xA18B Configure to Sync channels 0xA18C Allocate C6 Storage 0xA18D Before LV DDR4 0xA18E BR CPU BR before AP launch 0xA190 Install AP launched PPI 0xA191 BR after AP launch 0xA192 Befor...

Page 146: ...code calls out to locate a buffer 0xA1F2 After the memory code calls out to locate a buffer 0xA1F3 Before the memory code calls out to locate a buffer 0xA1F4 After the memory code calls out to locate a buffer 0xA1F5 Before the memory code calls out to locate a buffer 0xA1F6 After the memory code calls out to locate a buffer 0xA1F7 5 11 4 PMU Post Code Failed PMU training 0xA1F9 5 11 5 0xA5XX assig...

Page 147: ...eV2 ready to boot exit 0xA52A PspDxeV2 exit boot serivce entry 0xA52B PspDxeV2 exit boot serivce exit 0xA52C PspSmmV2 entry 0xA52D PspSmmV2 exit 0xA52E PspSmmV2 SwSmiCallBack entry build the S3 save area for resume 0xA52F PspSmmV2 SwSmiCallBack exit build the S3 save area for resume 0xA530 PspSmmV2 BspSmmResumeVector entry 0xA531 PspSmmV2 BspSmmResumeVector exit 0xA532 PspSmmV2 ApSmmResumeVector e...

Page 148: ...mand MboxBiosCmdHSTIQuery 0xA5C4 Before send C2P command MboxBiosCmdClrSmmLock 0xA5C7 Before send C2P command MboxBiosCmdPcieInfo 0xA5C8 Before send C2P command MboxBiosCmdGetVersion 0xA5C9 PSP C2P mailbox exit base 0xA5DX Cmd 0xA5D0 Wait C2P command MboxBiosCmdDramInfo finished 0xA5D1 Wait C2P command MboxBiosCmdSmmInfo finished 0xA5D2 Wait C2P command MboxBiosCmdSleep SxInfo finished 0xA5D3 Wait...

Page 149: ...t 0xA90B IOMMU AmdNbioIommu DXE driver entry 0xA90C AmdNbioIommu DXE driver exit 0xA90D ALIB AmdNbioALIB DXE driver entry 0xA90E AmdNbioALIB DXE driver exit 0xA90F SMU AmdSmuV8 PEIM driver entry 0xA910 AmdSmuV8 PEIM driver exit 0xA911 AmdSmuV8 DXE driver entry 0xA912 AmdSmuV8 DXE driver exit 0xA913 AmdSmuV9 PEIM driver entry 0xA914 AmdSmuV9 PEIM driver exit 0xA915 AmdSmuV9 DXE driver entry 0xA916 ...

Page 150: ...NbioBaseHookReadyToBoot Event exit 0xA95D NbioBaseHookPciIO Event entry 0xA95E NbioBaseHookPciIO Event exit 0xA95F 0xA980 0xA99F BR GNB Task GnbEarlyInterfaceCZ entry 0xA970 GnbEarlyInterfaceCZ exit 0xA971 PcieConfigurationInit entry 0xA972 PcieConfigurationInit exit 0xA973 GnbEarlierInterfaceCZ entry 0xA974 GnbEarlierInterfaceCZ exit 0xA975 PcieEarlyInterfaceCZ entry 0xA976 PcieEarlyInterfaceCZ e...

Page 151: ...Late exit 0xA993 GnbSmuServiceRequestV8 entry 0xA994 GnbSmuServiceRequestV8 exit 0xA995 5 11 7 0xACXX assigned for AGESA CCX Module CCX IDS IDS_HOOK_CCX_AFTER_AP_LAUNCH 0xAC10 CCX PEI entry 0xAC50 CCX downcore entry 0xAC51 CCX DXE entry 0xAC55 CCX MP service callback entry 0xAC56 CCX Read To Boot callback entry 0xAC57 CCX SMM entry 0xAC5D CCX PEI start to launch APs for S3 0xAC70 CCX PEI end of la...

Page 152: ...ch finished 0xAF0D FCH InitS3Late dispatch finished 0xAF0E FCH Pei Entry 0xAF10 FCH Pei Exit 0xAF11 FCH MultiFch Pei Entry 0xAF12 FCH MultiFch Pei Exit 0xAF13 FCH Dxe Entry 0xAF14 FCH Dxe Exit 0xAF15 FCH MultiFch Dxe Entry 0xAF16 FCH MultiFch Dxe Exit 0xAF17 FCH Smm Entry 0xAF18 FCH Smm Exit 0xAF19 FCH Smm Dispatcher Entry 0xAF20 FCH Smm Dispatcher Exit 0xAF21 FCH InitReset HwAcpi 0xAF40 FCH InitR...

Page 153: ...0xAF61 FCH InitMid LPC 0xAF62 FCH InitMid SPI 0xAF63 FCH InitMid eSPI 0xAF64 FCH InitMid SD 0xAF65 FCH InitMid eMMC 0xAF66 FCH InitMid SATA 0xAF67 FCH InitMid USB 0xAF68 FCH InitMid xGbE 0xAF69 FCH InitLate HwAcpi 0xAF70 FCH InitLate AB Link 0xAF71 FCH InitLate LPC 0xAF72 FCH InitLate SPI 0xAF73 FCH InitLate eSPI 0xAF74 FCH InitLate SD 0xAF75 FCH InitLate eMMC 0xAF76 FCH InitLate SATA 0xAF77 FCH I...

Page 154: ...L was not found 3 DXE Core Firmware Volume was not found 4 Recovery failed 4 S3 Resume failed 7 Reset PPI is not available 5 12 2 DXE Beep Codes of Beeps Description 1 Invalid password 4 Some of the Architectural Protocols are not available 5 No Console Output Devices are found 5 No Console Input Devices are found 6 Flash update is failed 7 Reset protocol is not available 8 Platform PCI resource r...

Page 155: ...BIOS Setup 155 This page intentionally left blank ...

Reviews: