11 Installation of MarkLED recess-mounted adapter in formwork
11.1 Mark, drill and fasten
Measure and mark centres of light module locations on the
formwork and drill with ø 5 mm.
Insert M5 screw with washer from the front through the
5mm bore in the formwork. Length of M5 screw 15mm +
formwork thickness.
Put sealing ring item no. Set 154914 onto recess-mounted
adapter. Screw the recess-mounted adapter to the back of
the formwork with the previously inserted M5 screw. Deter-
mine alignment of hose connections.
11.1.1 Alternative attachment with 4 screws
The MarkLED recess-mounted adapter can alternatively be
screwed onto the formwork from the back using 4 screws.
In this mounting variant, the screw tips projecting out of the
concrete after stripping must be cut off.
sealing ring