![Gifas-electric MarkLED 4 Installation Instructions Manual Download Page 30](http://html.mh-extra.com/html/gifas-electric/markled-4/markled-4_installation-instructions-manual_2222449030.webp)
MarkLED 4
Page 30 / 38
Created
03.10.2017
chal
Modified
28.11.2017
chal
Object-ID
850593
10.3 Connection
Strip cable conductors and the MarkLED to 11mm and con-
nect to the WAGO connection terminals item no. 162224.
Check if there is a small seal ring in the centre of the Mar-
kLED (missing seal rings must be refitted).
10.4 Sealing compound
The box must be filled with removable sealing compound
when not wall-mounted (first seal the tubes so that they are
not blocked by the compound)!
e.g. Bluegel. (Item no. 166534 1l container)
Hint
To ensure a tight installation, the contact surfaces of the
surface-mounted adapter must be absolutely clean.
Hint
Make sure that the conductors are not pinched.
Place and align MarkLED on the surface-mounted housing.
Press MarkLED on recess-mounted housing by hand using
lateral pressure and maintain pressure.
MarkLED must rest flush on the recess-mounted adapter.
Put on washer and tighten countersunk screw M5 with 2
Nm
torque.
Hint
Never try to tighten the MarkLED with excessive pressure.
This may damage the screw, thread or MarkLED.