Time recovery disabled.
The control unit does not make any calculations attempting to correctly make the
slow down phase before the complete opening and closing.
In case of motion inversion before the complete opening/closing, the control unit
makes the whole fast working time and then the slow down time.
Configuration suggested for big/heavy doors.
Time recovery enabled.
The control unit makes some calculation attempting to correctly make the slow
down phase before the complete opening and closing. This configuration causes,
after repeated motion inversions, long periods of slow down motion and possible
anti-crushing interventions not desired.
TIME
RECOVERY
0f
0n
Confirm
Learn
Confirm
Learn
Confirm
Learn
Confirm
Learn
/
0f
0n
rt
dt
FACTORY RESET
The factory reset procedure will bring back all the parameters to the default values and all the stored transmitters
will be deleted.
Procedure:
Ÿ
When the motor has stopped, push the b and - at the same time and release them.
Ÿ
5b
will appear on the display.
Ÿ
Push the b and - at the same time for 8 seconds.
Ÿ
Fr
will appear on the display
Ÿ
After 5 seconds, the control unit resets and 6 dashes will appear on the display.
WICKET DOOR SWITCH
In order to make the automated device inoperative, when the wicket door is open, connect it as shown in Fig. 10.
OVERHEAD DOOR
In order to automate an overhead door, it is necessary to use the curved arm, provided separately.
FORCED MOVEMENT OF THE DOOR
At any time, when the motor has stopped, it is possible to force an opening or closing manoeuvre.
WARNING:
During the forced movement of the door, all safety devices are disable.
Opening forced movement:
Pushing the for 8 seconds and keeping it pushed, the door will move slowly in opening.
When you release the , the door will stop.
Closing forced movement:
Pushing the button - for 8 seconds and keeping it pushed, the door will move slowly in closing.
When you released the button -, the door will stop.
OPERATION WITH BATTERIES
In order to assure the operation of the automatic device even in absence of line voltage, it is necessary to use the
BATTERY KIT FOR DIGITAL CONTROL UNIT, that you can purchase as optional with code AJ01510.
NOTE:
It is not allowed using the BATTERY KIT FOR ANALOG CONTROL UNIT with code AJ01480.
Summary of Contents for TAIMEN T12
Page 2: ...2 TAIMEN 2 3 1 1 2...
Page 3: ...50mm 2 1 3 4 5 3 TAIMEN 4 1 2 3 4 5 5 6 7 3...
Page 4: ...4 TAIMEN 2 600mm 50mm 1 3 4 1 3 4 2 5 6...
Page 5: ...5 TAIMEN 1 2 3 4 1 2 3 7a 8 7...
Page 46: ...46 NOTE NOTES TAIMEN...
Page 47: ...47 NOTE NOTES TAIMEN...