30
31
TAIMEN
TAIMEN
UK
UK
TECHNICAL SPECIFICATIONS
PRELIMINARY WARNINGS
Check that the door structure is in conformity with the regulations in force and that door movement is linear without
friction.
Preliminary checks:
Ÿ
Check that the door structure is sufficiently strong. In any case check that the weight and dimensions of the door fall
within the limits of use of the operator.
Ÿ
Check that the door can be moved manually without force (points of greatest friction) for the entire travel of the
door during both opening and closing.
Ÿ
A garage door is deemed to be well balanced and aligned if it:
§
requires an equivalent amount of applied force to either manually open or close.
§
requires no more than 150N (15Kg) of applied force to either manually open or close.
§
does not rise or fall more than 100mm when released at any point between fully open and fully closed
positions.
§
does not rub on any supporting or surrounding structures.
Ÿ
If the door is not a new installation, check the state of wear of all the components, repair or replace the defective or
worn parts and perform any other operations necessary.
Ÿ
Remove or make non-operating the existing locks.
Ÿ
The wall bracket carries all of the opening and closing thrust of the opener and as such must be securily fastened
to a rigid, structural member of the garage wall or ceiling.
The reliability and safety of the automated device are directy influenced by the status of door structure.
A = Opening time
C = Closing time
P = Overall pause time
A+C+P = Time between two
openings
Motor supply voltage
Radio receiver
On board, 100 transmitters max
Speed
Adjustable 90-125 mm/s
Slow downs
Automatic
Supply voltage
Max force
Operating temperature
Degree of protection
Operating frequency (%)
Operator
Type
TAIMEN T6
TAIMEN T12
Irreversible electromechanical gearmotor
220/230V 50-60 Hz
24Vdc
600 N
-20°C + 60°C
IP 20
30% (at 20°C)
1200 N
-20°C + 60°C
IP 20
30% (at 20°C)
%Fu =
x 100
A + C
A + C + P
Formula to calculate the
operating frequency
Max door surface
10 sqm
15 sqm
Power absorbed
MAX 80W
MAX 110W
Max door height
2,500 mm
2,500 mm
POSITION AND ASSEMBLY CONTROL UNIT-COURTESY LIGHT
DRIVE RAIL ASSEMBLY
WALL BRACKET INSTALLATION
BRACKET INSTALLATION ON THE DOOR
FIXING THE OPERATOR TO WALL BRACKET
Control unit-courtesy light can be installed in three different ways (Fig. 1) .
Ÿ
method A : at the end of the steel drive rail directly on the unit of motor pretensioning and power supply
Ÿ
Ÿ
(Fig. 1-A
and Fig.2).
method B: on the ceiling near the unit of motor pretensioning and power supply (Fig. 1-B).
method C: using the cable extension kit, everywhere (Fig. 1-C).
Ÿ
Compose the drive rail joining the three segments
by the two joints
Ÿ
Ÿ
Ÿ
Ÿ
(Fig. 3-2)
(Fig. 3-1), being sure that the drive rail
segments are completely put in the junctions.
Put in the assembled drive rail the swinging brackets support (Fig. 3-3) including roundhead screws and nuts.
Put the pretensioning units at the beginning and at the end of the assembled drive rail (Fig. 3-4) and (Fig. 3-6).
Fix the chain to the pretensioners using the included pins ( Fig. 3-5).
Use a 13mm socket wrench to adjust the pretensioning screw until the lower part of the screw head aligns with the
indicator on the pretensioning device ( Fig. 3-7).
Ÿ
Determine the highest point of the door during the movement and mark the level on the wall above the door
.
Ÿ
Determine the door center line and mark a vertical line on the wall above the door
Ÿ
Ÿ
Ÿ
( Fig. 4-1)
( Fig. 4-2).
Position the wall bracket ( Fig. 4-3) and ensure that the distance between the bracket base and the line previously
marked is not more than 50mm ( Fig. 4-1).
Mark on the wall the position of the two outer screws holes.
Fix the bracket to the wall ( Fig. 4-4).
Ÿ
Fix the handling bracket to a structural part of the door, using the two self-drilling screws 6mm x 50mm. Be sure that
the bracket is on the centre and on the top of the door
.
( Fig. 4-5)
Important Note: in order to avoid any damage to the operator, it is necessary to put the control unit - courtesy
light on a carton or some protective material
.
Ÿ
Be sure that the door is closed
.
Ÿ
Put the assembled
in line with the centre of the door and the control unit-courtesy light far
from the door
.
Ÿ
Lift the operator on the side of pretensioning unit
till the wall bracket
Ÿ
Fasten the pretensioning unit to the wall bracket using the long pin and a spring clip.
( Fig. 5-2)
( Fig. 5-1)
operator on the ground
( Fig. 5-2)
( Fig. 5-4)
( Fig. 5-4).
Summary of Contents for TAIMEN T12
Page 2: ...2 TAIMEN 2 3 1 1 2...
Page 3: ...50mm 2 1 3 4 5 3 TAIMEN 4 1 2 3 4 5 5 6 7 3...
Page 4: ...4 TAIMEN 2 600mm 50mm 1 3 4 1 3 4 2 5 6...
Page 5: ...5 TAIMEN 1 2 3 4 1 2 3 7a 8 7...
Page 46: ...46 NOTE NOTES TAIMEN...
Page 47: ...47 NOTE NOTES TAIMEN...