17
BARR500
UK
TECHNICAL DATA
Supply voltage
Load-bearing structure coating
Formula to calculate the
operating frequency
Operating temperature
Load-bearing structure dimensions
Power absorbed
Motor power supply
Load-bearing structure protection
Operator weight
Operating temperature
Degree of protection
Limit switch
Maximum boom length
Operating frequency (%Fu) at 20°C
Opening time to 90°
OPERATOR
Electric motor
24Vdc 1600 RPM
220/230Vac, single-phase, 50-60Hz
IP 44
24Vdc 3350 RPM
BARR524
BARR526
RAL 7040 polyester
MAX 200W
24Vdc
24Vdc
Cataphoresis
45 Kg (as sold)
A = Opening time
C = Closing time
P = Overall pause time
A + C + P = Time between two openings
-20°C +60°C
-20°C +60°C
-20°C +60°C
2 limit switches (open/close)
2 limit switches (open/close)
6m
2m
50%
60%
5s
%Fu= A + C x100
A + C + P
Maximum operating curve
The operating time based on the desired operating frequency can be derived from the graphs
(2)
and
(3)
.
Referring to figure
4.
1 -
Upright
2 -
Foundation plate
3 -
Spring
4 -
Balancing device with Cable
5 -
Electric motor
6 -
Reduction gear
7 -
Adjustable limit switch disc
8 -
Electronic control unit container
9 -
Hall-effect sensor
10 - Boom
11 - Spring adjustment nuts
Referring to Figures
5
,
6
and
7
.
NOMENCLATURE
DIMENSIONS
MAX 150W
1.8s
1117x325x255