11
SR2
UK
During the programming procedure, 1 or 2 remote-control codes can be memorised. A single code produces a
cyclical movement (Up/Down); using two codes, the upward and downward motion can be controlled separately.
The remote-control transmission codes are programmed as follows:
1. Push the
SEL
key for 1 second. The LED
D2
will start to blink;
2. Send the first code with the remote control chosen. The LED
D2
shall start to blink rapidly;
3. Send the second code with the remote control chosen. The LED
D2
stays on, signalling that
programming has been completed.
Note
: If the second code is not sent within 8 seconds, the control unit leaves the programming phase, selecting
the operating mode only with one remote-control code.
This procedure can be repeated until a maximum of 25 remote control commands are memorised. If all 25 codes
have been memorised by repeating the programming, then LED
D2
signals shall begin blinking, signalling that no
further memorisation operations are possible.
Remote-control commands can also be memorised without using the
SEL
key on the control unit. The procedure is
as follows:
1. Take a remote-control command already memorised and send the code to the control unit, keeping the
button pressed down for more than 20 seconds.
2. The control unit begins programming, triggering the blinking light and making some movements of the
shutter; new codes may be programmed during this phase by proceeding exactly as described above
starting from the second point.
Nota
: if no code has been memorised yet, then the remote programming phase may be activated by any remote
control command.
The control unit has a 230Vac 40W max. outlet for connection of a
“FLASHING LIGHT”
or
“COURTESY LIGHT”
.
The control unit is supplied by the manufacturer with the Flashing Light function enabled (
DIP-3-1 ON
).
Under the blinking mode, the 230 Vac outlet is activated every time the automation is in movement, for the duration of
the motor time.
To enable the courtesy light, switch
DIP-3-1 OFF
. When the courtesy light is activated, the control unit enables the
230V outlet for 180 second every time an opening/closing command is issued.
The control unit is supplied by the manufacturer without automatic closing.
To enable the automatic closing function, switch
DIP-3-2
and
DIP-3-3
following the logic shown in the table 1.
If don’t want the automatic closing, switch
DIP-3-2
and
DIP-3-3 OFF
.
PROGRAMMING OF THE REMOTE CONTROL
FLASHING LIGHT OR COURTESY LIGHT
PAUSE TIME: (PROGRAMMING THE AUTOMATIC CLOSING TIME, MAX. 90 SECONDS)
Summary of Contents for AS07000
Page 23: ...23 SR2 NOTES ...