(3) Installation requirements of Y-filter
Screw threads are G1/2''. The direction of installation should be consistent with the water inlet
direction, while the drain outlet of the filter should be downward.
(4) The water tank's supply water pressure ranges 0.15MPa ~ 0.5MPa. If the water inlet pressure
is always lower than 0.15MPa and in order to get higher water flow to meet water consumption
requirement, you need to add a booster pump at the water inlet so as to keep the water
pressure no lower than 0.15MPa; if the water inlet pressure is always higher than 0.5MPa, you
need to add a reducing valve of 0.5MPa at water inlet pipe so as to make sure the safety use
of the tank.
7. Electrical Wiring
ATTENTION
●
The appliance should use specified power cord, which should be required as the below table.
The voltage of power should also be suitable with the rated voltage requirement.
●
The power supply circuit should have ground wire, which should be connected with outside
ground effectively.
●
Wiring connection must be done by professional technical person and operate strictly according
to the electrical diagram.
●
Set up earth leakage protection according to the relevant national electrical equipment
standards.
●
Use all-pole disconnection device which has at least 3 mm contact separation when connecting
the power.
●
Double check the electrical circuit before connecting to the power supply.
●
Don't disconnect or disassemble the ground wire, nor use broken cables and switches under
any circumstances. If you find out any breakage, the power cord must be replaced as soon as
possible.
(1) Earth Leakage Protection
Fig.9
Power connection
Part 4: Instructions of Usage and Daily Operations
■
Control Panel Explanation
Fig.12
Control panel
①
Mode icons: It includes AUTOMATIC, HEAT PUMP and ASSISTANCE mode. When
user sets the mode, the corresponding icon lights up.
Clock icon: The clock icon lights up when timing on is set and the icons
①②③
mean
the
quantity
of
timings
set
.
Water temperature display area:
1.Display setting temperature and current temperature.
2.Display malfunction codes(refer to malfunction code table).
3.Display specific function codes: H1 means automatic
function; H2 means
anti-freezing function; H3 means boost function; H4 means photovoltaic function.
4.Display operating parameter codes.
disinfection
ON/OFF and TIMING icons: When user is setting timing, the icons ON/OFF and TIMING
both light up. The icon TIMING always lights up when the current time displays.
CLOCK button: Used to set time.
TIMING button: Used to set the timing.
T
ime
display area:
1.Display timings and current time.
2.Display current temperature under operating specific functions.
3.Display corresponding data when referring to parameters
UP and DOWN button: Used to adjust temperature and time.
MODE button: Used to set different modes.
ON/OFF button: Used to turn the appliance on or off.
No.
Description
⑩
⑨
⑧
⑦
⑥
⑤
④
③
②
⑩
⑨
⑧
⑦
⑥
⑤
④
③
②
①
Note:
When the air source heat pump water heater is running, if there is no operation or
malfunction for 35 seconds, the display only displays the current water temperature, while it
displays no value in stand-by status. When the water temperature indicator flashes continuously, it
means the appliance's disinfection function is on.
-14-
Instructions of Usage and Daily Operations
Installation
36
Summary of Contents for HTW HTW-AT-O-200VA2
Page 2: ......
Page 30: ...25 ...
Page 56: ...51 ...
Page 58: ...53 ...
Page 84: ...79 ...
Page 86: ...81 ...
Page 112: ...107 ...
Page 114: ...109 ...