Install the electricity guards provided by our company to the water inlet and outlet.
■
To Change the Installation Site
●
If you need to change the installation site, please contact your dealer or our local customer
service department.
Part 3: Installation
■
Basic Installation Tools and Materials Needed
N
ame
Hot water pipe
insulation material
Water pipe, flexible joint
Ball valve
Wire scissor or stripper
Straight screwdriver,
Phillips screwdriver
Pipe wrench
Depend on the length
of the heat pipe.
Depend on the actual need.
1 pc
1 pc
1 pc per each
2 pcs
QTY
To insulate.
Choose PPR pipes or PAP pipes.
To connect the tank inlet water pipes.
To trim thread and strip wire.
To disassemble the housing
cover and connect wires.
To connect the water pipes.
Usage
■
Dimensions
Sealing gasket
Inner tank
Water tank shell
Thermal Insulation
Anode rod
Plug for anode rod
Guidelines for replacing the anode
(magnesium) rod:
1. Turn off the power and the water inlet
valve.
2. Turn on the hot water valve or faucet,
so as to decrease the pressure of inner
tank.
3. Open the water outlet; drain out the
water until there is no water flow out.
4. Follow the instruction of the left figure,
remove the anode rod with a socket or a
wrench.
5. Replace the new anode rod: new
anode rod threads need to be coated
with screw sealant compatible for use on
sanitary and heating system. Place the
groove of plug with the original sealing
gasket or new specification one. Finally,
assemble anode rod.
6. When finishing the installation, heat
the water to
53
℃
, check whether there is
leakage around the installation position of
anode rod during the process.
ATTENTION
Fig.14
Replacing anode rod
Water inlet connector
Pressure relief
handle
Direction
Drainage hose
Drainage outlet
Cold water
inlet
Safety
valve
●
The pressure relief handle of safety
valve should be pulled once every six
months to remove the deposit calcium
and confirm the device is not clogged. Its
outlet water temperature may be high, so
be careful to avoid scolding.
●
The water may drip from the drainage
outlet of the device and that the drainage
hose must stay open to the atmosphere.
●
In case of that drainage hose freezes
in winter, which causes accident, please
handle the drainage hose with insulation
protection.
Fig.15
S
afety
valve
-19-
Installation
Repair and Maintenance
31
Part names:
1.
Air inlet
2.
Air outlet
3.
Control pan
4.
Housing cov
5. W
ater tank
6.
Water outlet - G 3/4" F
7.
Cover (Thermal cut-o
ut 93ºC)
8.
Magnesium rod (180
g
/
pc
)
9.
Solar sensor connector (water
temperatu
re
data for solar energy system)
10.
Solar energy in
- G 3/4" F
11.
Solar energy outlet - G 3/4" F
12.
Cover (Electric heating eleme
nt)
13. W
ater inlet - G 3/4" F
14. W
ater outlet - G 3/4" F
15.
Condensate out
- G 1/2" F