E40.0.01.6C-08 

Operating Manual EB-Logg 80CL 

page 4 of 16 

2.4  Safety guidelines 

This device has been designed and tested in accordance with the safety regulations for 
electronic devices. However, its trouble-free operation and reliability cannot be guaran-
teed unless the standard safety measures and special safety advises given in this manual 
will be adhered to when using the device. 

1. 

 

Install the displaying device according to the manufacturer's specifications and 
the valid standards and regulations. 

2. 

 

Modifications or repairs of the device may not be performed by the customer. 
For maintenance or repair the device must be sent to the manufacturer. 

3. 

 

Trouble-free operation and reliability of the device can only be guaranteed if the 
device is not subjected to any other climatic conditions than those stated under 
”Specification”. 

To protect the battery, the maximum permissible storage and transport 
temperature of the device is 70 °C

 

4. 

 

Trouble-free operation and reliability of the device can only be guaranteed if the 
device is not subjected to any other climatic conditions than those stated under 
“Specification”. 

5. 

 

When connecting the device to other devices (e.g. PC) the interconnection has to 
be designed most thoroughly as internal connections in third-party devices (e.g. 
connection GND with protective earth) may lead to undesired voltage potentials. 

6. 

 

If there is a risk whatsoever involved in running it, the device has to be switched 
off immediately and to be marked accordingly to avoid re-starting. 

Operator safety may be a risk if: 

  - there is visible damage to the device. 

  - the device is not working as specified. 

  - the device has been stored under unsuitable conditions for a longer time. 

In case of doubt, please return device to manufacturer for repair or maintenance. 

7. 

 

Do not use these products as safety or emergency stop devices or in any other 
application where failure of the product could result in personal injury or material 
damage. 
Failure to comply with these instructions could result in death or serious injury 
and material damage. 

8. 

 

This device must not be used at potentially explosive areas! 

9. 

 

This device must not be used at a patient for diagnostic or other medical pur-
pose. 

 

 

Summary of Contents for GREISINGER EB-Logg 80CL

Page 1: ...ik GmbH Hans Sachs Str 26 93128 Regenstauf GERMANY Tel 49 9402 9383 0 info greisinger de www greisinger de from from Version V2 7 Operating Manual EB Logg 80CL EB Logg 80CL E Data logger for humidity...

Page 2: ...Operating possibilities via software EASYBus Configurator 10 6 Battery life time and recording period 10 7 Operating displays 11 7 1 Measured value display 11 7 2 Logger status messages 11 7 3 System...

Page 3: ...ge This device must not be used at a patient for diagnostic or other medical purpose The liability and warranty of the manufacturer for damages and consequential damages are voided with misuse disrega...

Page 4: ...only be guaranteed if the device is not subjected to any other climatic conditions than those stated under Specification 5 When connecting the device to other devices e g PC the interconnection has to...

Page 5: ...tings 3 2 Notes on the logger s delivery status The delivered logger is in a sleep mode that means nothing is displayed and the power consumption is at its minimum When there is a communication with t...

Page 6: ...logger is recording BAT signals weak battery see chapter 7 AL signals an alarm state at minimum one channel SL signals an active sea level correction for the air pressure 4 2 Function of the buttons b...

Page 7: ...the display el ement MAX Note You can immediately switch to the next measuring channel pushing the button again Delete max value Push button for about 5 seconds CLr is displayed and the max values of...

Page 8: ...tart recording Push button for about 5 seconds The main display shows run The secondary display shows no To start recording select YES with the arrow keys button or and verify with Note If no key is p...

Page 9: ...rm your adjustments and to leave the menu Note If no key is pressed for more than 2 min the menu is quit without saving This setting allows the logger to be a substitute for outdated loggers in existi...

Page 10: ...an be only changed if the logger is stopped logger without logger data 5 5 Operating possibilities via software EASYBus Configurator The software EASYBus Configurator V2 0 is needed to change the conf...

Page 11: ...row AL signals an alarm state at minimum one channel The arrow SL signals an active sea level correction 7 2 Logger status messages At stand alone operation no EASYBus connected logger status messages...

Page 12: ...repair 7 4 Alarm and error messages The following messages correspond to a particular measuring channel and are dis played accordingly ALARM LOW The measured value is below the selected min alarm lim...

Page 13: ...RH Air pressure 1 0 mbar typ 2 5 mbar max Display two 4 digit LCD displays about 7 and 5 8 mm high Interface EASYBus Busload equals to 2 EASYBus elements Battery 1x fixed lithium cell Li SOCl2 3 6V 1...

Page 14: ...lowing European di rectives 2011 65 EU RoHS 2014 30 EU EMV directives Applied harmonized standards EN 50581 2012 EN 61326 1 2013 emissions level class B emi immunity according to table 1 additional er...

Page 15: ...delete data Problem A error message is displayed Error message Possible reason procedure remedy measuring range exceeded Measuring range of the chan nel has been exceeded Operate logger within its sp...

Page 16: ...es a General connection diagram for a relay with self induction recuperation diode b Connection information for GR 10 GNR 10 or GNR 232 A GND to be connected to terminal 11 of the GNR NPN to be connec...

Reviews: