To switch the
SMS-Module
on, the slide switch on the rear must be shifted to the right, until the symbol
can be seen.
Figure 1 – Switch on the right: Device is switched on
Now the device will start, the state is indicated by these LEDs:
GSM
(red) – shows the state of the GSM module:
Fast flashing (1s-period): Is searching for a radio network, not registered on the net yet
Slow flashing (3s-period): Is registered in the radio network
Supply
(green) – indicates that the external power supply is present
Power
(green) – indicates that the internal power is OK
Status
(yellow) – displays the current operational state of the
SMS-Module
:
Permanent off: Device is booting and initializing
1x Flash: Entering PIN is required
2x Flash: Entering PUK is required
3x Flash: Entering SMS service center number is required
4x Flash: No (valid) SIM-card present
5x Flash: Hardware defective
Permanent on: Ready, normal operation
In order to shut off the device the slide switch on the rear must be moved to the left (then the green LED
Supply
will turn off). It
is not sufficient to shut off the external power supply because the device has an internal lithium-ion-battery.
5 Adjust the SMS-Module
All settings are done by using a PC and our program
ProfiLuxControl II
with version 4.0.5.0 or higher. The newest version can
be downloaded from our homepage. To save settings to the SMS-module you have to click
Save
.
5.1 Establish a connection
In order that
ProfiLuxControl II
will search for the
SMS-module
during establishing a connection the checkmark
Search for
SMS-module
must be set.