background image

Thank you for purchasing a GGM product.
To ensure that you areusing this product correctly, make sure to first read this operation
manual thoroughly and familiarize yourself with allknowledge, safety information and 
precautions related tothe product. After you have read this operation manual, keep it 
at hand for reference whenneeded.

1. Safety precautions

In usingand operating the product, be sure to observe the following precautions. Failure to 
observe the precautions may result in electric shock, injury or fire. The following precautions
are very important and should be observed at all times.

 Do not use the product near explosive materials, combustible materials,flammable

    gas, corrosive materials, or anyplace where it may be splashed by water.
    Doing so may cause fire, electric shock or injury.

 Do not forcibly bend, pull or insert the motor lead wire.

    Doing so may cause fire or electric shock. 

 Do not move, install, connect or inspectthe product while an electric current

    is being applied. Be sure to only perform repair or installationwork after 
    cutting off the power supply. 
    Failure to do so may cause an electric shock. 

 H a v e   a   q u a l i f i e d   p e r s o n   w i t h   r e l e v a n t   k n o w l e d g e   i n s t a l l ,   c o n n e c t ,  

      o p e r a t e ,   c o n t r o l   a n d   c h e c k   t h e   p r o d u c t   f o r   f a i l u r e .    
    Doing so may cause fire, electric shock or injury.

 After cutting off the power supply, allow a full minute to elapse before touchingthe

    output terminal. Failure to do so may cause an electric shock. 

 Be sure to cut off the power supply when the power failure protection

    device or overheating protection device (thermal protector) is triggered. 
    Failure to do so may cause injury when the product re-starts without warning.

 Install the speed controller in the housing. Ground the protective ground

   terminal when it is installed. 
   Failure to do so may cause an electric shock or injury.

 Make sure thatthe AC power supply to the speed controlleris at the rated 

    voltage. Failure to do so may cause a fire or product damage.

 Do not disassemble or modify the motor orthe speed controller.  Failure to do so

    may cause an electric shock or injury.

Ignoring thesewarnings may cause 
death or serious injury.

Warning

2

Summary of Contents for GUS Series

Page 1: ...Factory 22 Gyeongin ro 3beon gil Bucheon si Gyeonggi do Republic of Korea Tel 82 32 664 7790 Fax 82 32 611 7791 Attached research institute No 2 factory 180 Oksan ro Bucheon si Gyeonggi do Republic of...

Page 2: ...urrent is being applied Be sure to only perform repair or installationwork after cutting off the power supply Failure to do so may cause an electric shock Have a qualified person with relevant knowled...

Page 3: ...power supply immediately to stop the operation The controller has no protection device It is recommended to install an over current protection device earth leakage circuit breaker or overheating prot...

Page 4: ...ion cable that islongerthan 2 5m as degradation of the motor functionmay occur KE 05 KE 10 KE 15 KE 20 0 5m 1m 1 5m 2m Item name length of extension cable 3 Specifications Property Model name Rated vo...

Page 5: ...ions of the product G U S C 60 06 6W 15 15W 25 25W 40 40W 60 60W 90 90W 120 120W 180 180W C Single Phase AC220V 50 60Hz AC230V 50 60Hz AC240V 50 60Hz U Single Phase AC110V 50 60Hz AC115V 50 60Hz Semi...

Page 6: ...he front dial Variable speed range 50Hz 200 1430 r min 60Hz 200 1730 r min Various operation modes can be set through the parameter setting The motor and the speed controller are packaged separately s...

Page 7: ...Dial Operation switch Displays the rotation speed and parameters When you movethe operation switch to RUN the motor rotates when you movethe operation switchtoSTAND BY themotorstops Changes the rotat...

Page 8: ...SW2 to change the direction when the power supply switch SW1 is ON it may damage the controller 1 Connect the motor connector 2 Connect the COM and CW terminals CW operation Refer to the CCW operation...

Page 9: ...peed to rotate the dial Display of rotation speed When the power is supplied again the motor will rotate at the newrotation speed When you movethe operation switch to STAND BY the motor will stop Cont...

Page 10: ...g the parameter mode press and hold the dial PUSH SET for 2 seconds When you rotate the dial the data value will change Set the desired data value Press the dial PUSH SET to enter the selected paramet...

Page 11: ...en the power is supplied The motor does not rotate There is abnormality or excessive vibration in the motor operation The motor rotates but the speed cannot be changed The motor does not run immediate...

Page 12: ...Leader of geared motor GGM CO LTD http www ggm co kr Headquarters 1st Factory 22 Gyeongin ro 3beon gil Bucheon si Gyeonggi do Republic of Korea TEL 032 664 7790 FAX 032 611 7791 Attached research ins...