background image

▶ Two-way operation wiring

▶ External operation wiring

1) Connect the motor connector.

2) Install the power supply switch (SW1)

and the forward and reserve rotation

exchange switch (SW2) and change the 

rotation direction.  

Instantaneous forward and reverse

rotation are unavailable. 

Turn off the power supply switch (SW1)

and when the motor has stopped 

completely, replace the switch (SW2) to

change the direction.

Caution) If you replace the switch (SW2)

to change the direction when the power

supply switch (SW1) is ON, it may damage

the controller.

1) Connect the motor connector.

2) Connect the ②COM and

③CW terminals. (CW operation)

Refer to the CCW operation and two-way

operation wiring.

3) Connect the AC power to terminals

⑥ and ⑦.

4) 

Install the external operation 

switch (SW1). 

When you move the front operation 

switch to STAND-BY and turn on the 

external operation switch (SW1), 

the motor operates.

When you turn off the external operation

switch (SW1), the motor stops.

SWITCH

SW1

SW2

Switch contact capacity 

AC 125V or 250V 5A or higher

AC 125V or 250V 5A or higher

8

Motor connector

Motor connector

Summary of Contents for GUS Series

Page 1: ...Factory 22 Gyeongin ro 3beon gil Bucheon si Gyeonggi do Republic of Korea Tel 82 32 664 7790 Fax 82 32 611 7791 Attached research institute No 2 factory 180 Oksan ro Bucheon si Gyeonggi do Republic of...

Page 2: ...urrent is being applied Be sure to only perform repair or installationwork after cutting off the power supply Failure to do so may cause an electric shock Have a qualified person with relevant knowled...

Page 3: ...power supply immediately to stop the operation The controller has no protection device It is recommended to install an over current protection device earth leakage circuit breaker or overheating prot...

Page 4: ...ion cable that islongerthan 2 5m as degradation of the motor functionmay occur KE 05 KE 10 KE 15 KE 20 0 5m 1m 1 5m 2m Item name length of extension cable 3 Specifications Property Model name Rated vo...

Page 5: ...ions of the product G U S C 60 06 6W 15 15W 25 25W 40 40W 60 60W 90 90W 120 120W 180 180W C Single Phase AC220V 50 60Hz AC230V 50 60Hz AC240V 50 60Hz U Single Phase AC110V 50 60Hz AC115V 50 60Hz Semi...

Page 6: ...he front dial Variable speed range 50Hz 200 1430 r min 60Hz 200 1730 r min Various operation modes can be set through the parameter setting The motor and the speed controller are packaged separately s...

Page 7: ...Dial Operation switch Displays the rotation speed and parameters When you movethe operation switch to RUN the motor rotates when you movethe operation switchtoSTAND BY themotorstops Changes the rotat...

Page 8: ...SW2 to change the direction when the power supply switch SW1 is ON it may damage the controller 1 Connect the motor connector 2 Connect the COM and CW terminals CW operation Refer to the CCW operation...

Page 9: ...peed to rotate the dial Display of rotation speed When the power is supplied again the motor will rotate at the newrotation speed When you movethe operation switch to STAND BY the motor will stop Cont...

Page 10: ...g the parameter mode press and hold the dial PUSH SET for 2 seconds When you rotate the dial the data value will change Set the desired data value Press the dial PUSH SET to enter the selected paramet...

Page 11: ...en the power is supplied The motor does not rotate There is abnormality or excessive vibration in the motor operation The motor rotates but the speed cannot be changed The motor does not run immediate...

Page 12: ...Leader of geared motor GGM CO LTD http www ggm co kr Headquarters 1st Factory 22 Gyeongin ro 3beon gil Bucheon si Gyeonggi do Republic of Korea TEL 032 664 7790 FAX 032 611 7791 Attached research ins...

Reviews: