▶ Two-way operation wiring
▶ External operation wiring
1) Connect the motor connector.
2) Install the power supply switch (SW1)
and the forward and reserve rotation
exchange switch (SW2) and change the
rotation direction.
Instantaneous forward and reverse
rotation are unavailable.
Turn off the power supply switch (SW1)
and when the motor has stopped
completely, replace the switch (SW2) to
change the direction.
Caution) If you replace the switch (SW2)
to change the direction when the power
supply switch (SW1) is ON, it may damage
the controller.
1) Connect the motor connector.
2) Connect the ②COM and
③CW terminals. (CW operation)
Refer to the CCW operation and two-way
operation wiring.
3) Connect the AC power to terminals
⑥ and ⑦.
4)
Install the external operation
switch (SW1).
When you move the front operation
switch to STAND-BY and turn on the
external operation switch (SW1),
the motor operates.
When you turn off the external operation
switch (SW1), the motor stops.
SWITCH
SW1
SW2
Switch contact capacity
AC 125V or 250V 5A or higher
AC 125V or 250V 5A or higher
8
Motor connector
Motor connector