3.
Lift the panel using the handle to remove and gain access to the filters.
4.
Using both hands, pull the used filter by its frame along the track and out of the unit.
Remove the remaining filters in the same manner as the first filter.
WARNING
Treat used filters and any other paint-contaminated items as flammable products and dispose of them
safely.
NOTE
Pay attention to the orientation of the filter inside the unit.
5.
Making sure the filter is oriented the same way, slide the new GFS pocket filters along the track into the
air heater.
6.
Reattach the panel and secure it with the four wing-head thumb screws.
Replace air heater filters (SpaceSaver)
WARNING
Before servicing, lockout/tagout the air heater, including the main electrical service and the main gas
supply.
CAUTION
SpaceSaver air heaters are located on the booth’s roof and must be accessed using a scissor lift or ladder.
Follow safety guidelines for harnesses and heights.
1.
On the roof of your paint booth, survey the side of the air heater with various access panels. The
access panel to the filters is behind the gas train access panel.
Service and maintenance