Replace the exhaust filters in a semi-downdraft booth
The exhaust filters are located in the filter racks of the exhaust bridge chamber.
1.
Remove and safely dispose of used filter media.
WARNING
Treat used filters and any other paint-contaminated items as flammable products and dispose of them
safely.
2.
Place new filters onto the filter grids. Orient the filters so that the wave side is facing you.
A: Exhaust filter
B: Air-leaving side (dense side of filter)
C: Air-entering side
D: Filter grid
E: Rubber tip on grid corner
F: Airflow
Replace the intake filters
NOTE
Perform this task at recommended intervals (see “Inspect filters and replace as needed” (page 16)) and any
time visual inspection or booth performance indicates that the filter needs to be replaced.
NOTE
Verify that the correct replacement filters are available before removing used filter media. Before servicing,
remove and lockout/tagout the main electrical source.
The intake filters are inserted into the filter racks in the ceiling of each bay.
Service and maintenance
Global Finishing Solutions
18
239-062 rev 5